Debuncher Cooling Limitations to Stacking (open access)

Debuncher Cooling Limitations to Stacking

During the January studies period we performed studies to determine the effect that debuncher cooling has on the stacking rate. Two different sets of measurements were made separated by about a week. Most measurements reported here are in PBAR log 16, page 243-247. These measurements were made by changing the accelerator timeline to give about 6 seconds between 29's, and then gating the cooling systems to simulate reduced cycle times. For the measurement of the momentum cooling effectiveness the gating switches could not be made to work, so the timeline was changed for each measurement. The cooling power of all three systems was about 800 watts for the tests reported here. We now regularly run at 1200 watts per system.
Date: August 13, 1991
Creator: Halling, Mike