A safety assessment was performed to determine if potential accidents at the 854 Complex at Site 300 could present undue hazards to the general public, personnel at Site 300, or have an adverse effect on the environment. The credible accidents that might have an effect on these facilities or have off-site consequences were considered. These were earthquake, extreme wind (including missiles), lightning, flood, criticality, high explosive (HE) detonation that disperses uranium and beryllium, spontaneous oxidation of plutonium, explosions due to finely divided particles, and a fire. Seismic and extreme wind (including missiles) analyses indicate that the buildings are basically sound. The lightning protection system is in the process of being upgraded to meet AMCR 385-100. These buildings are located high above the dry creek bed so that a flood is improbable. The probability of high explosive detonation involving plutonium is very remote since the radioactive materials are encased and plutonium and HE are not permitted concurrently in the same area at Site 300. (The exception to this policy is that explosive actuating devices are sometimes located in assemblies containing fissile materials. However, an accidental actuation will not affect the safe containment of the plutonium within the assembly.) There is a …