General purpose heat source (GPHS) clad vent set (CVS) formability study
Primarily, Mound was to evaluate both improved-iridium and standard-flight iridium blanks with respect to current GPHS-CVS manufacturing processes and provide example-weld-quality CVS to the Savannah River Plant (SRP) for its weldability study. Additionally, Mound's practice of performing a final outgassing (1500/sup 0/C for 1 hr) of CVS was evaluated with respect to metallurgical properties of iridium cups and electron-beam (EB) welding characteristics of CVS subassembly components.
Date:
November 3, 1986
Creator:
Forrest, M. A.; McDougal, J. R. & Saylor, R. W.