Resource Type

Month

5 Matching Results

Results open in a new window/tab.

ENVIRONMENTAL REACTIVITY OF SOLID STATE HYDRIDE MATERIALS (open access)

ENVIRONMENTAL REACTIVITY OF SOLID STATE HYDRIDE MATERIALS

In searching for high gravimetric and volumetric density hydrogen storage systems, it is inevitable that higher energy density materials will be used. In order to make safe and commercially acceptable condensed phase hydrogen storage systems, it is important to understand quantitatively the risks involved in using and handling these materials and to develop appropriate mitigation strategies to handle potential material exposure events. A crucial aspect of the development of risk identification and mitigation strategies is the development of rigorous environmental reactivity testing standards and procedures. This will allow for the identification of potential risks and implementation of risk mitigation strategies. Modified testing procedures for shipping air and/or water sensitive materials, as codified by the United Nations, have been used to evaluate two potential hydrogen storage materials, 2LiBH{sub 4} {center_dot} MgH{sub 2} and NH{sub 3}BH{sub 3}. The modified U.N. procedures include identification of self-reactive substances, pyrophoric substances, and gas-emitting substances with water contact. The results of these tests for air and water contact sensitivity will be compared to the pure material components where appropriate (e.g. LiBH{sub 4} and MgH{sub 2}). The water contact tests are divided into two scenarios dependent on the hydride to water mole ratio and heat transport characteristics. …
Date: April 23, 2009
Creator: Gray, J & Donald Anton, D
System: The UNT Digital Library
FITNESS-FOR-SERVICE ASSESSMENT FOR A RADIOACTIVE WASTE TANK THAT CONTAINS STRESS CORROSION CRACKS (open access)

FITNESS-FOR-SERVICE ASSESSMENT FOR A RADIOACTIVE WASTE TANK THAT CONTAINS STRESS CORROSION CRACKS

Radioactive wastes are confined in 49 underground storage tanks at the Savannah River Site. The tanks are examined by ultrasonic (UT) methods for thinning, pitting, and stress corrosion cracking in order to assess fitness-for-service. During an inspection in 2002, ten cracks were identified on one of the tanks. Given the location of the cracks (i.e., adjacent to welds, weld attachments, and weld repairs), fabrication details (e.g., this tank was not stress-relieved), and the service history the degradation mechanism was stress corrosion cracking. Crack instability calculations utilizing API-579 guidance were performed to show that the combination of expected future service condition hydrostatic and weld residual stresses do not drive any of the identified cracks to instability. The cracks were re-inspected in 2007 to determine if crack growth had occurred. During this re-examination, one indication that was initially reported as a 'possible perpendicular crack <25% through wall' in 2002, was clearly shown not to be a crack. Additionally, examination of a new area immediately adjacent to other cracks along a vertical weld revealed three new cracks. It is not known when these new cracks formed as they could very well have been present in 2002 as well. Therefore, a total of twelve …
Date: April 23, 2009
Creator: Wiersma, B; James Elder, J; Rodney Vandekamp, R & Charles Mckeel, C
System: The UNT Digital Library
IMPLEMENTATION OF CHEMWARE HORIZON LIMS AT THE WSCF (WASTE SAMPLING AND CHARACTERIZATION) LABORATORY (open access)

IMPLEMENTATION OF CHEMWARE HORIZON LIMS AT THE WSCF (WASTE SAMPLING AND CHARACTERIZATION) LABORATORY

None
Date: April 23, 2009
Creator: TF, DALE
System: The UNT Digital Library
Time-Dependent Measure of a Nano-Scale Force-Pulse Driven by the Axonemal Dynein Motors in Individual Live Sperm Cells (open access)

Time-Dependent Measure of a Nano-Scale Force-Pulse Driven by the Axonemal Dynein Motors in Individual Live Sperm Cells

Nano-scale mechanical forces generated by motor proteins are crucial to normal cellular and organismal functioning. The ability to measure and exploit such forces would be important to developing motile biomimetic nanodevices powered by biological motors for Nanomedicine. Axonemal dynein motors positioned inside the sperm flagellum drive microtubule sliding giving rise to rhythmic beating of the flagellum. This force-generating action makes it possible for the sperm cell to move through viscous media. Here we report new nano-scale information on how the propulsive force is generated by the sperm flagellum and how this force varies over time. Single cell recordings reveal discrete {approx}50 ms pulses oscillating with amplitude 9.8 {+-} 2.6 nN independent of pulse frequency (3.5-19.5 Hz). The average work carried out by each cell is 4.6 x 10{sup -16} J per pulse, equivalent to the hydrolysis of {approx}5,500 ATP molecules. The mechanochemical coupling at each active dynein head is {approx}2.2 pN/ATP, and {approx}3.9 pN per dynein arm, in agreement with previously published values obtained using different methods.
Date: April 23, 2009
Creator: Allen, M J; Rudd, R E; McElfresh, M W & Balhorn, R
System: The UNT Digital Library