2005 Habitat Evaluation Procedure (HEP) Report for the Carey Creek Project (open access)

2005 Habitat Evaluation Procedure (HEP) Report for the Carey Creek Project

In August 2002, the Habitat Evaluation Procedure (HEP) was used to determine baseline habitat suitability on the Carey Creek property, an acquisition completed by the Kalispel Tribe of Indians in December 2001. Evaluation species and appropriate models include bald eagle, black-capped chickadee, Canada goose, mallard, yellow warbler, and white-tailed deer. Habitat Suitability Index (HSI) values were visually estimated and agreed upon by all HEP team members. The Carey Creek Project provides a total of 172.95 Habitat Units (HUs) for the species evaluated. Conifer forest habitat provides 4.91 HUs for bald eagle, black-capped chickadee, and white-tailed deer. Forested wetlands provide 52.68 HUs for bald eagle, black-capped chickadee, mallard, and white-tailed deer. Scrub-shrub wetlands provide 2.82 HUs for mallard, yellow warbler and white-tailed deer. Wet meadow and grassland meadow provide 98.13 HUs for mallard and Canada goose. Emergent wetlands provide 11.53 HUs for mallard, muskrat, and Canada goose. Open water provides 2.88 HUs for Canada goose, mallard, and muskrat. The objective of using HEP at the Carey Creek Project and other protected properties is to document the quality and quantity of available habitat for selected wildlife species. In this way, HEP provides information on the relative value of the same area at …
Date: June 2005
Creator: Entz, Ray
System: The UNT Digital Library
Report on Applicability of Residential Ventilation Standards in California (open access)

Report on Applicability of Residential Ventilation Standards in California

The California Energy Commission is considering updating its requirements for residential ventilation in the next round of its energy code, known as ''Title 24''. This report contains recommendations for potential changes to the code. These recommendations must be further developed into specific wording before they can be formally considered. Residential ventilation standards always address local and whole-house ventilation rates and some basic source control requirements, but there are many interactions with building systems that must also be considered. McKone and Sherman [8] laid out a set of additional issues that should be addressed before any specific changes to the code should be made. Those key issues included the following: Adventitious Air Flow; Air Distribution; Filtration and Air Cleaning; Occupant Acceptability and Control; Outdoor Air; Peak Demand; Unusual Sources and High-Polluting Events; and Window Operation. McWilliams and Sherman reviewed the literature on residential ventilation and in particular these key issues. They also reviewed codes, standards and guidelines relevant to residential ventilation. That literature serves as the technical basis for this report.
Date: June 1, 2005
Creator: Sherman, Max H. & McWilliam, Jennifer A.
System: The UNT Digital Library