Magnetic Core Tests for Pulsed Operation at 30 Nanoseconds Pulse Width
The magnetic properties of core materials ae investigated for a pulse width of 30 nanoseconds. Methods of testing which are necessitated by the sort pulse width are explained and the design of the pulser which is capable of 0.2 megawatt peak power is described. The data obtained if evaluated and presented for the various materials which were tested.