PLUTONIUM OXALATE DISK FILTER AND FILTER MEDIA STUDIES (open access)

PLUTONIUM OXALATE DISK FILTER AND FILTER MEDIA STUDIES

for filtration of plutonium oxalate slurries. A scalpel produces a slit in the filter precoat, leading to increased filtration in this slit, and the oxalate is removed by a doctor knife; this technique results in prolonged blowback cycles and more uniform delivery of filtered oxalate to subsequent processing steps. Several types of filter media were tested, and rigid porous aluminum oxide was found to be the best one. (D.L.C.)
Date: October 19, 1959
Creator: Rey, G.
System: The UNT Digital Library
Post irradiation examination of KER-1-3 seven rod cluster fuel elements (RM-277) (open access)

Post irradiation examination of KER-1-3 seven rod cluster fuel elements (RM-277)

Two coextruded, Zr-2 clad, natural uranium, seven rod cluster fuel elements were irradiated to a calculated exposure of 1250 MWD/T in the KER Facility and discharged 1-16-59. The fuel elements were NPR candidate fuel and examination was requested to determine the behavior of coextruded, Zr-2 clad, natural uranium irradiated at core temperatures of approximtely 425{degree}C. The elements were transferred to the Radiometallurgy Laboratory 2-25-59. The elements demonstrated excellent in reactor performance with no significant changes in either the fuel or the hardware. Detailed examination of the central rod and two peripheral rods from one of the clusters showed no microcracks in the uranium. Moderate growth was observed in the fuel at the unrestricted rod ends.
Date: October 19, 1959
Creator: Gruber, W. J.
System: The UNT Digital Library
Supplement C to Production Test IP-250-A, Irradiation of Zircaloy-2 jacketed tube and tube elements in the KER loop (open access)

Supplement C to Production Test IP-250-A, Irradiation of Zircaloy-2 jacketed tube and tube elements in the KER loop

The objective of this Supplement described in this report to Pt-IP-250-A is to d enriched tube-and-tube elements will develop pitting corrosion on the Zircaloy-2 jackets when irradiated in pH 10 water. The measurement of dimensional changes in the fuel elements and the observation of the effect of irradiation on the uranium and bond area are also objectives of the test, but secondary in importance to identifying a pitting corrosion problem in NPR quality water, if one exists.
Date: October 19, 1959
Creator: Kratzer, W. K.
System: The UNT Digital Library
Measurement of heat from the graphite in a dummy-charged KER loop (open access)

Measurement of heat from the graphite in a dummy-charged KER loop

None
Date: October 19, 1959
Creator: Kratzer, W. K.
System: The UNT Digital Library
TRANSIENT TESTS OF HNPF PROTOTYPE SODIUM PUMP DRIVES (open access)

TRANSIENT TESTS OF HNPF PROTOTYPE SODIUM PUMP DRIVES

The objectives of this study were to demonstrate that the pump speed control system will respond as defined in the equipment specifications and to determine optimum values of controlling variables that will minimize the oscillations that occur in the Na flow rate when transient signals are imposed on the pump speed control system. (W.L.H.)
Date: October 19, 1959
Creator: Atz, R. W.
System: The UNT Digital Library
A VISUAL STUDY OF THE CORROSION OF DEFECTED ZIRCALOY-2-CLAD FUEL SPECIMENS BY HOT WATER (open access)

A VISUAL STUDY OF THE CORROSION OF DEFECTED ZIRCALOY-2-CLAD FUEL SPECIMENS BY HOT WATER

The failure of defected Zircaloy-2-clad uranium and uranium -2 wt.% zircorium fuel specimens in high-purity high-pressure water at 200 to 345 deg C was observed in a windowed antcclave. Time-lapse color motion pictures were taken to provide a record of the progressive changes ending in the complete disintegration of the core material in the specimens. Continuous measurement of the pressure increase caused by accumulation of hydrogen served to monitor the progress of the reaction when clouding of the water by corrosion products made visual observation impossible. The nature of the attack of all specimens was similar, although the time at which different stages occurred varied. Following an induction period, the first evidence of attack was the slow formation of a blister in the cladding area surrounding the defect. Eventually, a copions evolution of hydrogen occurried at the base of the swollen area. In general, a crack could be seen in the cladding at this stage. Catastrophic failure of the specimen followed swiftly. The time required for each phase of the reaction was reduced as the temperature was raised. Initial swelling occurred after about 24 min at 345 deg C but only after 8 hr at 200 deg C. Diffusion-treated uranium2 …
Date: October 19, 1959
Creator: Stephan, Elmer F.; Miller, Paul D. & Fink, Frederick W.
System: The UNT Digital Library
Accuracy of Volume Measurements in a Large Process Vessel (open access)

Accuracy of Volume Measurements in a Large Process Vessel

The Non-Production Fuel Reprocessing Program involves the chemical processing of valuable reactor fuels received from privately owned power reactors. It is necessary therefore, to accurately measure the fuel material received in order to insure proper payment to reactor operator and to provide the Atomic Energy Commission with appropriate accountability data. The volume measurement study described herein was conducted in order to determine the limits of accuracy that could be obtained in measuring relatively large volumes of solution under plant processing conditions.
Date: October 19, 1959
Creator: Pleasance, C. L.
System: The UNT Digital Library
Plutonium Oxalate Disk Filter and Filter Media Studies (open access)

Plutonium Oxalate Disk Filter and Filter Media Studies

Presently rotary drum filters are being used for plutonium oxalate slurry filtration in the 234-5 Building. Changing of the filter cloth used on a rotary drum is a time consuming operation which involves ever increasing radiation exposure to maintenance personnel. Consequently, studies were conducted in the 321 Building on a disk type filter which could be adapted for simple and quick ("one-nut") replacement of the filter medium.
Date: October 19, 1959
Creator: Rey, George
System: The UNT Digital Library
A Rotating Source for Calibration Purposes (open access)

A Rotating Source for Calibration Purposes

This paper discusses a remotely operated system developed to transport (raise and lower) a 1/2 gram radium gamma radiation source for calibration of the HAPO film badges and finger rings. The system employs the rotometer principle for positioning the source for operating purposes. An accurate timer is utilized to assure the desired exposure time.
Date: October 19, 1959
Creator: Kocher, L. F.
System: The UNT Digital Library