Nuclear Instrumentation Module (NIM) standard logic processor as a portal signal analyzer (open access)

Nuclear Instrumentation Module (NIM) standard logic processor as a portal signal analyzer

A general purpose electronic logic processor has been designed into a 2 wide NIM (Nuclear Instrumentation Module) bin module. The unit utilizes a microprocessor to achieve necessary versatility. The processor's first use is as a new generation signal analyzer for use in radiometric personnel and vehicle portal monitors. Significant improvements have been obtained in sensitivity and stability over existing analog discriminators. The new analyzer is presently being used to update personnel and vehicle portal monitoring systems.
Date: November 4, 1978
Creator: Minges, G.P.
System: The UNT Digital Library