ATLAS parameter study (open access)

ATLAS parameter study

The purpose of this study is to make an independent assessment on the parameters chosen for the ATLAS capacitor bank at LANL. The contractor will perform a study of the basic pulsed power parameters of the ATLAS device with baseline functional parameters of >25 MA implosion current and <2.5 microsecond current risetime. Nominal circuit parameters held fixed will be the 14 nH from the vacuum interface to the load, and the nominal load impedances of 1 milliohm for slow loads and 10 milliohms for fast loads. Single Ended designs, as opposed to bipolar designs, will be studied in detail. The ATLAS pulsed power design problem is about inductance. The reason that a 36 MJ bank is required is that such a bank has enough individual capacitors so that the parallel inductance is acceptably low. Since about half the inductance is in the bank, and the inductance and time constant of the submodules is fixed, the variation of output with a given parameter will generally be a weak one. In general, the dl/dt calculation demonstrates that for the real system inductances, 700 kV is the optimum voltage for the bank to drive X-ray loads. The optimum is broad, and there is …
Date: September 3, 1994
Creator: Adler, R.J.
System: The UNT Digital Library