States

104 Matching Results

Results open in a new window/tab.

Design Method of Cold-Formed Steel Framed Shear Wall Sheathed by Structural Concrete Panel

Access: Use of this item is restricted to the UNT Community
The objective of this research is developing a new method of design for cold-formed steel framed shear wall sheathed by ¾" thick USG structural panel concrete subfloor using a predictive analytical model and comparing the results obtained from the model with those achieved from real testing to verify the analytical model and predicted lateral load-carrying capacity resulted from that. Moreover, investigating the impact of various screw spacings on shear wall design parameter such as ultimate strength, yield strength, elastic stiffness, ductility ratio and amount of energy dissipation is another purpose of this research.
Date: December 2019
Creator: Ashkanalam, Aida
Object Type: Thesis or Dissertation
System: The UNT Digital Library
A Study on the System Reliability of Cold-Formed Steel Roof Trusses (open access)

A Study on the System Reliability of Cold-Formed Steel Roof Trusses

This thesis presents a research project aimed at advancing the treatment of cold-formed steel (CFS) structural reliability in roof trusses. Structural design today relies almost exclusively on component-level design, so structural safety is assured by limiting the probability of failure of individual components. Reliability of the entire system is typically not assessed, so in a worst-case scenario the system reliability may be less than the component reliability, or in a best-case scenario the system reliability may be much greater than the component reliability. A roof truss itself, is a subsystem with several possible failure modes that are being studied in this test program. These trusses are constructed of CFS members that nest with one another at the truss nodes and are connected by drilling fasteners through the mated surfaces, as well as having steel sheathing fastened to the top chords for lateral bracing. Presented in this paper is a series of full-scale static tests on single cold-formed steel roof trusses with a unique experimental setup. The test specimens were carefully monitored to address multiple failure modes: buckling of the top chord, buckling of the truss webs, and any connection failures. This research includes the experimental results, the computed system reliability …
Date: May 2017
Creator: Johnson, Adam M.
Object Type: Thesis or Dissertation
System: The UNT Digital Library
Design of a Machine Condition Monitoring System with Bluetooth Low Energy (open access)

Design of a Machine Condition Monitoring System with Bluetooth Low Energy

This thesis discusses the design considerations for a machine conditioning sensor utilizing Bluetooth low energy (BLE).
Date: May 2017
Creator: Tompkins, Nicholas
Object Type: Thesis or Dissertation
System: The UNT Digital Library
Hydrophobicity of Magnetite Coating on Low Carbon Steel (open access)

Hydrophobicity of Magnetite Coating on Low Carbon Steel

Superhydrophobic coatings (SHC) with excellent self-cleaning and corrosion resistance property is developed on magnetite coated AISI SAE 1020 steel by using a simple immersion method. Roughness measurement, scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD), contact angle measurement (CAM), energy dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (FTIR), potentiodynamic polarization test, electrochemical impedance spectroscopy (EIS), and qualitative characterization of self-cleaning behavior, antifouling property and durability of the coatings are assessed. A water contact angle as high as 152o on the coated surface with excellent self-cleaning and resistivity to corrosion and good longevity in atmospheric air is obtained. Self-cleaning test results prove that these surfaces can find applications in large scale production of engineering materials. Potentiodynamic polarization tests and EIS tests confirm that the superhydrophobic low carbon steel surfaces have better resistance to corrosion compared to bare steel and magnetite coated steel in 3.5% NaCl solution. But the longevity of the coated steel surfaces in 3.5% salt solution is limited, which is revealed by the immersion durability test. However, hydrophobic coatings (HC) have better stability in normal tap water, and it can stay unharmed up to 15 days. Finally, hydrophobic coatings on low carbon steel surface retains hydrophobic …
Date: August 2018
Creator: Akhtar, Mst Alpona
Object Type: Thesis or Dissertation
System: The UNT Digital Library
The Measurement of the Third-order Elastic Constants for La3ga5sio14 (Lgs) and La3ga55ta05o14 (Lgt) Single Crystal (open access)

The Measurement of the Third-order Elastic Constants for La3ga5sio14 (Lgs) and La3ga55ta05o14 (Lgt) Single Crystal

Recently, the development of electronic technology towards higher frequencies and larger band widths has led to interest in finding new piezoelectric materials, which could be used to make filters with larger pass band widths and oscillators with better frequency stability. Langasite (La3Ga5SiO14, LGS) and its isomorphs have enticed considerable attention of researchers as a potential substrate material for piezoelectric device applications because of its high frequency stability and fairly good electromechanical coupling factors for acoustic wave devices. Nonlinear effect including drive level dependence, mode coupling, force-frequency effect and electroelasic effect are critical for the design of these devices. Third-order elastic constants (TOEC) play an important role in a quantitative analysis of these nonlinear effects. In particular these elastic constants are of great importance when the BAW (Bulk Acoustic Wave) and SAW (Surface Acoustic Wave) sensors of force, acceleration and so on are designed. Until now Langasite (LGS) and Langatate (LGT) crystal resonators have been qualified in terms of quality factor, temperature effect, isochronism defect and material quality. One of the most important advantages of those crystals is that they will not undergo phase transitions up to its melting temperature of 1450°. Presently there is no data on TOEC of LGT …
Date: December 2013
Creator: Karim, Md Afzalul
Object Type: Thesis or Dissertation
System: The UNT Digital Library

Cold-Formed Steel Member Connections Using BAC Screw Fasteners

Access: Use of this item is restricted to the UNT Community
In this project, the main research objective is intend to seek criteria for evaluating the capacity of BAC screw fasteners with mixed configuration of waterproof seal washer, sealer tape and different pre-drill holes to determine shear and tension strength values for the screws used in cold-formed steel connections. The thesis presents the design methods and test program conducted to investigate the behavior and strength of the screw connections in shear and tension test. Test results were compared with AISI design provisions to determine if new design equations will be developed for those screws used in BAC cooling tower applications. LRFD resistance factors and ASD safety factors were investigated to the proposed design equations.
Date: May 2019
Creator: Li, Xun
Object Type: Thesis or Dissertation
System: The UNT Digital Library
Topology and Lattice-Based Structural Design Optimization for Additively Manufactured Medical Implants (open access)

Topology and Lattice-Based Structural Design Optimization for Additively Manufactured Medical Implants

Topology-based optimization techniques and lattice structures are powerful ways to accomplish lightweight components with enhanced mechanical performance. Recent developments in additive manufacturing (AM) have led the way to extraordinary opportunities in realizing complex designs that are derived from topology and lattice-based structural optimization. The main aim of this work is to give a contribution, in the integration between structural optimization techniques and AM, by proposing a setup of a proper methodology for rapid development of optimized medical implants addressing oseeointegration and minimization of stress shielding related problems. The validity of the proposed methodology for a proof of concept was demonstrated in two real-world case studies: a tibia intramedullary implant and a shoulder hemi prosthetics for two bone cancer patients. The optimization was achieved using topology optimization and replacement of solid volumes by lattice structures. Samples of three lattice unit cell configurations were designed, fabricated, mechanically tested, and compared to select the most proper configuration for the shoulder hemi prosthesis. Weight reductions of 30% and 15% were achieved from the optimization of the initial design of the tibia intramedullary implant and the shoulder hemiprosthesis respectively compared to initial designs. Prototypes were fabricated using selective laser melting (SLM) and direct light processing …
Date: May 2019
Creator: Peto, Marinela
Object Type: Thesis or Dissertation
System: The UNT Digital Library
Microfluidic-Based Fabrication of Photonic Microlasers for Biomedical Applications (open access)

Microfluidic-Based Fabrication of Photonic Microlasers for Biomedical Applications

Optical microlasers have been used in different engineering fields and for sensing various applications. They have been used in biomedical fields in applications such as for detecting protein biomarkers for cancer and for measuring biomechanical properties. The goal of this work is to propose a microfluidic-based fabrication method for fabricating optical polymer based microlasers, which has advantages, over current methods, such us the fabrication time, the contained cost, and the reproducibility of the microlaser's size. The microfluidic setup consisted of microfluidic pumps and a flow focusing droplet generator chip made of polydimethylsiloxane (PDMS). Parameters such as the flow rate (Q) and the pressure (P) of both continuous and dispersed phases are taken into account for determining the microlaser's size and a MATLAB imaging tool is used to reduce the microlaser's diameter estimation. In addition, two applications are discussed: i) electric field measurements via resonator doped with Di-Anepps-4 voltage sensitive dye, and ii) strain measurements in a 3D printed bone-like structure to mimic biomedical implantable sensors.
Date: December 2019
Creator: Cavazos, Omar
Object Type: Thesis or Dissertation
System: The UNT Digital Library