Diameter Measurements of Slugs Before and After Prolonged Heat Treatment (open access)

Diameter Measurements of Slugs Before and After Prolonged Heat Treatment

Abstract: "Diameter measurements of 25 slugs taken before and after a prolonged heat treatment showed no evidence of differences that would indicate blistering. The average effects of the treatment was different for the various slugs. Large differences in diameter measurements between slugs. Large differences in diameter between slugs and significant differences between indices and positions were found."
Date: February 16, 1948
Creator: Bennett, Carl A. & Lane, J. J.
System: The UNT Digital Library
A Microdetermination of Uranium by Ferric Sulfate Titration (open access)

A Microdetermination of Uranium by Ferric Sulfate Titration

Abstract: "Following nitrate removal by means of a three-stage hydrochloric acid digestion, uranium was reduced with chromous sulfate reagent. In an inert atmosphere, the quadrivalent uranium was titrated at 80-95[degrees] with standard ferric sulfate solution. The end point was obtained with a potentiometric cell including a platinum in-titrant reference electrode and a platinum indicator electrode. Application was made to various low leverl uranium solutions. For samples containing 1 - 12 milligrams or uranium, less than one percent error may be expected. Iron and chromium do not interfere."
Date: February 16, 1949
Creator: Christopherson, E. W.
System: The UNT Digital Library
The Valve Actuated Pulse Column Design (open access)

The Valve Actuated Pulse Column Design

Abstract: "The valve-actuated pulse column is employed to give phase separation on each half cycle in the countercurrent flow cycle and provides independent control over each step in the cycle. The dependence on temperature of operation, on pulse frequency and amplitude, and on plate design and spacing has been studied for extraction and stripping of uranium with tributyl phosphate in a hydrocarbon diluent. It is found that the efficiency increases quite significantly as the temperature is raised regardless of the direction of transfer and this increased efficiency is accompanied by greater operational freedom. A decrease in hole size, decrease in plate separation and increase in frequency all lead to higher efficiency in agreement with the concept that small drops continually formed coalesced and reformed, lead to maximum interphase transfer. The high extraction efficiency of the column is probably aided further by the relatively sharp pulse produced."
Date: February 16, 1953
Creator: Burger, L. L. & Clark, L. H.
System: The UNT Digital Library
Decontamination of Dissolver Vent Gases at Hanford (open access)

Decontamination of Dissolver Vent Gases at Hanford

The preceding report follows an extensive study made at Hanford of methods and equipment to remove effectively the dissolver vent gases.
Date: February 16, 1951
Creator: Blasewitz, A. G.; Carlisle, R. V.; Judson, B. F.; Katzer, M. F.; Kurtz, E. F.; Schmidt, W. C. et al.
System: The UNT Digital Library