Evaluation of NaK as the Primary Coolant for the SNAP II System (open access)

Evaluation of NaK as the Primary Coolant for the SNAP II System

An evaluation was made of the use of NaK as the primary coolant for the SNAP-2 system. Pumping-power limitations based on the mercury Rankine cycle are analyzed. Problems pertinent to any design-specification modifications are reviewed.
Date: July 10, 1959
Creator: Wallerstedt, R.
System: The UNT Digital Library
The Palmolive cycle at Hanford (open access)

The Palmolive cycle at Hanford

The Palmolive program is directed toward the recovery of neptunium-237 and production of plutonium-238. The neptunium is recovered during the chemical processing of irradiated uranium and is purified and fabricated into target elements. The target elements are irradiated to produce plutonium-238 by neutron capture of neptunium-237 and are processed to provide plutonium for shipment to the final customer and neptunium for recycle within the system. This report summarizes a preliminary engineering study of the technical and economic factors involved in installing long-term Palmolive manufacturing facilities at Hanford to meet the reduced production goals. Prime emphasis is placed on the process technology and plant equipment requirements for fabricating and reprocessing neptunium target elements on a production basis. The relationships of these phases of the target cycle to the recovery and purification of virgin neptunium in the Purex Plant and irradiation of target elements in the Hanford reactors are reviewed in the light of the reduced plutonium-238 demands.
Date: July 10, 1959
Creator: Beard, S. J. & Judson, B. F.
System: The UNT Digital Library
Determination of Li$xup 6$ in Aqueous Solution by Neutron Activation Analysis (open access)

Determination of Li$xup 6$ in Aqueous Solution by Neutron Activation Analysis

A method for determining the concentration of Li/sup 6/ in aqueous solution was tested using the nuclear reactions Li/sup 6/(n, alpha )H and O/sup 16/(H/sup 3/,n)F/sup 18/. Annihilation gamma radiation of induced 1.87-hr F/ sup 18/ radioactivity was counted with a welltype scintillation counter, and the radioactivity per millimole of lithium was found to be independent of lithium concentration below about 0.2 moles/liter. The sensitivity limit for detecting lithium is less than 0.1 micromole (0.0075 micromole Li/sup 6/). (auth)
Date: July 10, 1959
Creator: Winchester, J. W.; Bate, L. C. & Leddicotte, G. W.
System: The UNT Digital Library