Resource Type
Partner
Collection
Office of Scientific & Technical Information Technical Reports
20
Texas Digital Newspaper Program
6
Tocker Foundation Grant
5
Oklahoma Digital Newspaper Program
2
Altus Times-Democrat
1
Brazoria County Area Newspapers
1
The Baytown Sun
1
Chickasha Newspaper Collection
1
Hockley County Area Newspaper Collection
1
Hidden Selections of Houston’s African American and Jewish Heritage
1
6 More
Serial/Series Title
Levelland and Hockley County News-Press
1
Polk County Enterprise
1
Rev. William A. Lawson papers (MS 532)
1
San Antonio Board of Adjustment Monthly Report
1
San Antonio Monthly Permit Report
1
San Antonio Monthly Reports
1
The Altus Times
1
The Alvin Sun
1
The Baytown Sun
1
The Express-Star
1
2 More
Country
States
Results:
1 - 24 of
31
next
Seminole Sentinel (Seminole, Tex.), Vol. 93, No. 92, Ed. 1 Sunday, September 3, 2000
Semiweekly newspaper from Seminole, Texas that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Dow, M. Gene & Fisher, David
Object Type:
Newspaper
System:
The Portal to Texas History
Polk County Enterprise (Livingston, Tex.), Vol. 118, No. 69, Ed. 1 Sunday, September 3, 2000
Semi-weekly newspaper from Livingston, Texas that includes local, state and national news along with advertising.
Date:
September 3, 2000
Creator:
White, Barbara
Object Type:
Newspaper
System:
The Portal to Texas History
[Saniei Family Videos, No. 14 - Jasmine Saniei Videotapes her Family]
This home movie excerpt documents young Jasmine Saniei videotaping and interviewing her mother Patricia and father Saeed (Michael) about their activities at home. Saeed (Michael) is in the kitchen and Patricia is relaxing on the couch.
Date:
September 3, 2000
Creator:
Saniei
Object Type:
Video
System:
The Portal to Texas History
Fisher Helium Purge Flow Control Valve and Relay
None
Date:
September 3, 2000
Creator:
MISKA, C.
Object Type:
Report
System:
The UNT Digital Library
Reotemp Pressure Indicator Local Pressure Indication in the 15 PSIG SCHe System
These 0-30 psig range pressure indicators are located in the SCHe supply piping after PCV 5*23 and before PCV 5*27. The pressure indicators provide information on the pressure being maintained between the two PCVs. This design is used for each of the SCHe supply lines.
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
NUPRO Process Vent and MCO Check Valve Prevent Backflow from Process Vent into MCO
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Worcester Solenoid Actuated Gas Operated MCO Isolation Valves
These valves are 1 inch gas-operated full-port ball valves incorporating a solenoid and limit switches as integral parts of the actuator that are used in different process streams within the CVDF hood. The valves fail closed (on loss of pressure or electrical) for MCO isolation to either reduce air in leakage or loss of He. All valves have coupling for transverse actuator mounting.
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Ashcroft Pressure Switch Monitor for Low SCHe Purge Pressure
These 0-15 psig pressure switches are located in the SCHe helium purge lines after PCV-5*23 and before PCV-5*27. The pressure switches monitor the pressure being maintained between the two PCVs and actuate on low pressure of 15 psig. This design is used for each of the SCHe supply lines. Electronic output signal is NON-SAFETY (GS).
Date:
September 3, 2000
Creator:
Van Katwijk, Carl
Object Type:
Report
System:
The UNT Digital Library
Flex Hose Connectors to SCHe Helium Bottles Sche-TK-5*01 and 5*02 and 5*03 and 5*04
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Fike MCO Pressure Safety Element
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Whitey Gauge and Root Valves (VPS)
These valves are 1/2 inch ball valves fabricated of 316 stainless steel: Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the Vacuum Pumping and Helium System.
Date:
September 3, 2000
Creator:
MISKA, C.
Object Type:
Report
System:
The UNT Digital Library
Whitey SCHE Gauge and Root Valves
These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Swagelok Quick Disconnect TW-QD-*132 Tempered Water to MCO Transfer Cask
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Whitey Swagelok SCHe ball valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent
These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function betwen SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Concoa SCHe Pressure Regulators and Reotemp Pressure Gauge (SCHe Tank Outlet)
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Griswold Tempered Water Flow Regulator Valves Used as Anti Siphon Valves
FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus.
Date:
September 3, 2000
Creator:
MISKA, C.
Object Type:
Report
System:
The UNT Digital Library
Aschroft Pressure Switch Monitor for Low SCHe Supply Bottle Pressure
These pressure switches are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. The switches monitor the SCHe supply bottle pressure and are set to alarm at 2200 psig. There is one switch for each SCHe supply (4). Electronic output signal is NON-SAFETY (GS).
Date:
September 3, 2000
Creator:
Van Katwijk, Carl
Object Type:
Report
System:
The UNT Digital Library
Krohne Flow Indicator and High Flow Alarm Local Indicator and High Flow Alarm of Helium Flow from the SCHe Purge Lines C and D to the Process Vent
Flow Indicators/alarms FI/FSH-5*52 and -5*72 are located in the process vent lines connected to the 2 psig SCHe purge lines C and D. They monitor the flow from the 2 psig SCHe purge going to the process vent. The switch/alarm is non-safety class GS.
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library
Levelland and Hockley County News-Press (Levelland, Tex.), Vol. 22, No. 45, Ed. 1 Sunday, September 3, 2000
Semiweekly newspaper from Levelland, Texas that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Rigg, John
Object Type:
Newspaper
System:
The Portal to Texas History
The Baytown Sun (Baytown, Tex.), Vol. 78, No. 282, Ed. 1 Sunday, September 3, 2000
Daily newspaper from Baytown, Texas that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Cash, Wanda Garner
Object Type:
Newspaper
System:
The Portal to Texas History
Altus Times (Altus, Okla.), Vol. 101, No. 150, Ed. 1 Sunday, September 3, 2000
Daily newspaper from Altus, Oklahoma that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Bush, Michael
Object Type:
Newspaper
System:
The Gateway to Oklahoma History
Alvin Sun-Advertiser (Alvin, Tex.), Vol. 109, No. 71, Ed. 1 Sunday, September 3, 2000
Weekly newspaper from Alvin, Texas that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Schwind, Jim & Holton, Kathleen
Object Type:
Newspaper
System:
The Portal to Texas History
The Express-Star (Chickasha, Okla.), Ed. 1 Sunday, September 3, 2000
Daily newspaper from Chickasha, Oklahoma that includes local, state, and national news along with advertising.
Date:
September 3, 2000
Creator:
Bush, Kent
Object Type:
Newspaper
System:
The Gateway to Oklahoma History
NUPRO inline instrument air filters
None
Date:
September 3, 2000
Creator:
Miska, C. R.
Object Type:
Report
System:
The UNT Digital Library