New Mexico's energy resources '81. Annual report of Bureau of Geology in the Mining and Minerals Division of New Mexico Energy and Minerals Department (open access)

New Mexico's energy resources '81. Annual report of Bureau of Geology in the Mining and Minerals Division of New Mexico Energy and Minerals Department

Although production of U/sub 3/O/sub 8/ declined only slightly in 1980, New Mexico's share of domestic production has declined from 48% in 1976 to 35% in 1980. Production projections indicate a continued decline in 1981 and lower production until at least 1984. New Mexico has 41% of total domestic reserves producible in the $50-per-lb cost category. In keeping with the anticipated steady depletion of reserves, production of crude oil in New Mexico was 69.9 million bls, a 6.3% decline in production from 1979. Condensate production of 5.4 million bbls in 1980, however, represented an increase of 7% from 1979 production. Although natural gas production was the lowest since 1970 and declined by 2.6% from 1979 production, 1980 was the 15th year that production exceeded 1 trillion cu ft. Despite declines in production, the valuation of oil and gas production has increased significantly with oil sales doubling from the previous year and gas sales increasing by $409 million because of higher prices. Reserves have been estimated to be 959 million bbls of crude oil and 17.667 trillion cu ft of natural gas. Production of 19.5 million short tons of coal in 1980 represented a 33% increase over 1979 production and an …
Date: September 3, 1981
Creator: Arnold, E. C. & Hill, J. M. (comps.)
Object Type: Report
System: The UNT Digital Library
Vacuum system for Advanced Test Accelerator (open access)

Vacuum system for Advanced Test Accelerator

The Advanced Test Accelerator (ATA) is a pulsed linear electron beam accelerator designed to study charged particle beam propagation. ATA is designed to produce a 10,000 amp 50 MeV, 70 ns electron beam. The electron beam acceleration is accomplished in ferrite loaded cells. Each cell is capable of maintaining a 70 ns 250 kV voltage pulse across a 1 inch gap. The electron beam is contained in a 5 inch diameter, 300 foot long tube. Cryopumps turbomolecular pumps, and mechanical pumps are used to maintain a base pressure of 2 x 10/sup -6/ torr in the beam tube. The accelerator will be installed in an underground tunnel. Due to the radiation environment in the tunnel, the controlling and monitoring of the vacuum equipment, pressures and temperatures will be done from the control room through a computer interface. This paper describes the vacuum system design, the type of vacuum pumps specified, the reasons behind the selection of the pumps and the techniques used for computer interfacing.
Date: September 3, 1981
Creator: Denhoy, B.S.
Object Type: Article
System: The UNT Digital Library
Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2 (open access)

Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2

A human factors engineering preliminary design review of the Saint Lucie Unit 2 control room was performed at the site on August 3 through August 7, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The review team included human factors consultants from BioTechnology, Inc., Falls Church, Virginia, and from Lawrence Livermore National Laboratory (University of California), Livermore, California.
Date: September 3, 1981
Creator: Peterson, L. Rolf; Lappa, David A. & Moore, James W.
Object Type: Report
System: The UNT Digital Library