Process Vessel Precision and Accuracy Estimates (open access)

Process Vessel Precision and Accuracy Estimates

The following is an attempt to explain the method by which the precision associated with an observed volume reading in a process vessel (E-12, C-1) should be calculated based upon a regression analysis of cumulative data. There are two types of volume measurement consists of estimating the total volume in a vessel at some inventory time. A transfer measurement consists of estimating the volume between two levels within a tank.
Date: March 2, 1959
Creator: Hough, C. G.