Resource Type

Energy Consumption and Expenditure Projections by Population Group on the Basis on the Annual Energy Outlook 2000 Forecast. (open access)

Energy Consumption and Expenditure Projections by Population Group on the Basis on the Annual Energy Outlook 2000 Forecast.

The changes in the patterns of energy use and expenditures by population group are analyzed by using the 1993 and 1997 Residential Energy Consumption Surveys. Historically, these patterns have differed among non-Hispanic White households, non-Hispanic Black households, and Hispanic households. Patterns of energy use and expenditures are influenced by geographic and metropolitan location, the composition of housing stock, economic and demographic status, and the composition of energy use by end-use category. As a consequence, as energy-related factors change across groups, patterns of energy use and expenditures also change. Over time, with changes in the composition of these factors by population group and their variable influences on energy use, the impact on energy use and expenditures has varied across these population groups.
Date: May 31, 2001
Creator: Poyer, D. A. & Sciences, Decision and Information
System: The UNT Digital Library
Feasibility of In Situ Redox Manipulation of Subsurface Sediments for RDX Remediation at Pantex (open access)

Feasibility of In Situ Redox Manipulation of Subsurface Sediments for RDX Remediation at Pantex

This laboratory study was conducted to assess RDX (hexahydro-1,3,5-trinitro-1,3,5 triazine) abiotic degradation by chemically reduced sediments and other geochemical aspects of the application of this technology to remediation of RDX contamination in groundwater at the U.S. DOE Pantex facility...
Date: December 31, 2001
Creator: Szecsody, James E.; Fruchter, Jonathan S.; Mckinley, Mark A.; Resch, Charles T. & Gilmore, Tyler J.
System: The UNT Digital Library
Performance Demonstration Program Plan for Nondestructive Assay of Boxed Wastes for the TRU Waste Characterization Program (open access)

Performance Demonstration Program Plan for Nondestructive Assay of Boxed Wastes for the TRU Waste Characterization Program

The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP for boxed waste assay systems. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are …
Date: January 31, 2001
Creator: Office, Carlsbad Field
System: The UNT Digital Library
Advanced Emissions Control Development Program (open access)

Advanced Emissions Control Development Program

The primary objective of the Advanced Emissions Control Development Program (AECDP) is to develop practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (HAPs, or air toxics) from coal-fired boilers. This objective is being met by identifying ways to effectively control air toxic emissions through the use of conventional flue gas cleanup equipment such as electrostatic precipitators (ESPs), fabric filters (fabric filters), and wet flue gas desulfurization (wet FGD) systems. Development work initially concentrated on the capture of trace metals, hydrogen chloride, and hydrogen fluoride. Recent work has focused almost exclusively on the control of mercury emissions.
Date: March 31, 2001
Creator: Farthing, G. A.; Amrhein, G. T.; Kudlac, G. A.; Yurchison, D. A.; McDonald, D. K. & Milobowski, M. G.
System: The UNT Digital Library
Hanford Immobilized LAW Product Acceptance Testing: Tanks Focus Area Results (open access)

Hanford Immobilized LAW Product Acceptance Testing: Tanks Focus Area Results

Immobilizing low-activity waste (LAW) stored at Hanford site will result in approximately 200 000 m3 of waste glass. It must be demonstrated that this glass can adequately retain radionuclides and prevent contamination of the surrounding environment. A study is being performed to determine the effect of glass composition on its capability to withstand the conditions in the Hanford site burial scenario. To predict the long-term corrosion behavior of waste glass, it is necessary to study the composition and properties of alteration products. The vapor hydration test (VHT) and product consistency test (PCT) were selected as the methods to accelerate the corrosion process and to form alteration products. VHT and PCT was performed on 75 glasses, of which 45 were designed to systematically vary the composition. VHTs were conducted at temperatures ranging from 90?C to 300?C. Alteration rates for most glasses are being determined at 200?C. Selected glasses were tested at different temperatures to determine the effect of temperature on the assemblage of alteration products and the apparent alteration rates. PCTs were performed at a glass surface area to solution volume ratio (S/V) of 2000 m-1 for 7 d and at a S/V of 20 000 m-1 for 10, 100, 1000, …
Date: December 31, 2001
Creator: Vienna, John D.; Hrma, Pavel R.; Jiricka, Antonin; Smith, Donald E.; Lorier, Troy H.; Reamer, Irene A. et al.
System: The UNT Digital Library
Technology Potential of Thermal Energy Storage (TES) Systems in Federal Facilities (open access)

Technology Potential of Thermal Energy Storage (TES) Systems in Federal Facilities

This document presents the findings of a technology market assessment for thermal energy storage (TES) in space cooling applications. The potential impact of TES in Federal facilities is modeled using the Federal building inventory with the appropriate climatic and energy cost data. In addition, this assessment identified acceptance issues and major obstacles through interviews with energy services companies (ESCOs), TES manufacturers, and Federal facility staff.
Date: July 31, 2001
Creator: Chvala, William D., Jr.
System: The UNT Digital Library
Authentication Procedures - The Procedures and Integration Working Group (open access)

Authentication Procedures - The Procedures and Integration Working Group

Authentication is how we establish trust in monitoring systems and measurements to verify compliance with, for example, the storage of nuclear weapons material. Authentication helps assure the monitoring party that accurate and reliable information is provided by any measurement system and that any irregularities are detected. The U.S. is developing its point of view on the procedures for authentication of monitoring systems now planned or contemplated for arms reduction and control applications. The authentication of a system utilizes a set of approaches, including: functional testing using trusted calibration sources, evaluation of documentation, evaluation of software, evaluation of hardware, random selection of hardware and software, tamper-indicating devices, and operational procedures. Authentication of measurement systems should occur throughout their lifecycles, starting with the elements of design, and moving to off-site authentication, on-siste authentication, and continuing with authentication following repair. The most important of these is the initial design of systems. Hardware and software design criteria and procurement decisions can make future authentication relatively straightforward or conversely very difficult. Facility decisions can likewise ease the procedures for authentication since reliable and effective monitoring systems and tampering indicating devices can help provide the assurance needed in the integrity of such items as measurement systems, …
Date: May 31, 2001
Creator: Kouzes, Richard T.; Bratcher, Leigh; Gosnell, Tom; Langner, Diana; MacArthur, D.; Mihalczo, John T. et al.
System: The UNT Digital Library
Improving a Gripper End Effector (open access)

Improving a Gripper End Effector

This paper discusses the improvement made to an existing four-bar linkage gripping end effector to adapt it for use in a current project. The actuating linkage was modified to yield higher jaw force overall and particularly in the critical range of jaw displacement
Date: January 31, 2001
Creator: Mullen, O Dennis; Smith, Christopher M. & Gervais, Kevin L.
System: The UNT Digital Library
Sulfur Partitioning During Vitrification of INEEL Sodium Bearing Waste: Status Report (open access)

Sulfur Partitioning During Vitrification of INEEL Sodium Bearing Waste: Status Report

The sodium bearing tank waste (SBW) at Idaho National Engineering and Environmental Laboratory (INEEL) contains high concentrations of sulfur (roughly 5 mass% of SO3 on a nonvolatile oxide basis). The amount of sulfur that can be feed to the melter will ultimately determine the loading of SBW in glass produced by the baseline (low-temperature, joule-heated, liquid-fed, ceramic-lined) melter. The amount of sulfur which can be fed to the melter is determined by several major factors including: the tolerance of the melter for an immiscible salt layer accumulation, the solubility of sulfur in the glass melt, the fraction of sulfur removed to the off-gas, and the incorporation of sulfur into the glass up to it?s solubility limit. This report summarizes the current status of testing aimed at determining the impacts of key chemical and physical parameters on the partitioning of sulfur between the glass, a molten salt, and the off-gas.
Date: July 31, 2001
Creator: Darab, John G.; Graham, Dennis D.; Macisaac, Brett D.; Russell, Renee L.; Smith, Harry D.; Vienna, John D. et al.
System: The UNT Digital Library
Transient Inverse Calibration of Hanford Site-Wide Groundwater Model to Hanford Operational Impacts - 1943 to 1996 (open access)

Transient Inverse Calibration of Hanford Site-Wide Groundwater Model to Hanford Operational Impacts - 1943 to 1996

This report describes a new initiative to strengthen the technical defensibility of predictions made with the Hanford site-wide groundwater flow and transport model. The focus is on characterizing major uncertainties in the current model. PNNL will develop and implement a calibration approach and methodology that can be used to evaluate alternative conceptual models of the Hanford aquifer system. The calibration process will involve a three-dimensional transient inverse calibration of each numerical model to historical observations of hydraulic and water quality impacts to the unconfined aquifer system from Hanford operations since the mid-1940s.
Date: May 31, 2001
Creator: Cole, Charles R.; Bergeron, Marcel P.; Wurstner, Signe K.; Thorne, Paul D.; Orr, Samuel & Mckinley, Mathew I.
System: The UNT Digital Library
Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001 (open access)

Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001

As part of the Leak Detection, Monitoring and Mitigation (LDMM) program conducted by CH2M HILL 105-A during FY 2001. These tests are being conducted to assess the applicability of these methods (Electrical Resistance Tomography [ERT], High Resolution Resistivity [HRR], Cross-Borehole Seismography [XBS], Cross-Borehole Radar [XBR], and Cross-Borehole Electromagnetic Induction [CEMI]) to the detection and measurement of Single Shell Tank (SST) leaks into the vadose zone during planned sluicing operations. The testing in FY 2001 will result in the selection of up to two methods for further testing in FY 2002. In parallel with the geophysical tests, a Partitioning Interwell Tracer Test (PITT) study will be conducted simultaneously at the Mock Tank to assess the effectiveness of this technology in detecting and quantifying tank leaks in the vadose zone. Preparatory and background work using Cone Penetrometer methods (CPT) will be conducted at the Mock Tank site and an adjacent test area to derive soil properties for groundtruthing purposes for all methods.
Date: July 31, 2001
Creator: Barnett, D. Brent; Gee, Glendon W. & Sweeney, Mark D.
System: The UNT Digital Library
Measurement of Helium-3/Helium-4 Ratios in Soil Gas at the 618-11 Burial Ground (open access)

Measurement of Helium-3/Helium-4 Ratios in Soil Gas at the 618-11 Burial Ground

Seventy soil gas-sampling points were installed around the perimeter of the 618-11 Burial Ground, approximately 400 feet downgradient of well 699-13-3A, and in four transects downgradient of the burial ground to a maximum distance of 3,100 feet. Soil gas samples were collected and analyzed for helium-3/helium-4 ratios from these 70 points. Helium-3/helium-4 ratios determined from the soil gas sampling points showed significant enrichments, relative to ambient air helium-3 concentrations. The highest concentrations were located along the northern perimeter of the burial ground. Helium-3/helium-4 ratios (normalized to the abundances in ambient air) ranged from 1.0 to 62 around the burial ground. The helium-3/helium-4 ratios from the 4 transect downgradient of the burial ground ranged from 0.988 to 1.68. The helium-3/helium-4 ratios from around the burial ground suggest there is a vadose zone source of tritium along the north side of the burial ground. This vadose zone source is likely the source of tritium in the groundwater. The helium-3/helium-4 ratios also suggest the groundwater plume is traveling east-northeast from the burial ground and the highest groundwater tritium value may be to the north of well 699-13-3A. Finally, there appears to be no immediately upgradient sources of tritium impacting the burial ground since …
Date: October 31, 2001
Creator: Olsen, Khris B.; Dresel, P Evan & Evans, John C.
System: The UNT Digital Library
Gas Releases During Saltcake Dissolution for Retrieval of Single-Shell Tank Waste (open access)

Gas Releases During Saltcake Dissolution for Retrieval of Single-Shell Tank Waste

It is possible to retrieve a large fraction of soluble waste from the Hanford single-shell waste tanks (SST) by dissolving it with water. This retrieval method will be demonstrated in U-107 and S-112 in the next few years. If saltcake dissolution proves practical and effective, many of the saltcake SSTs may be retrieved by this method. Many of the SSTs retain a large volume of flammable gas that will be released into the tank headspace as the waste dissolves. This report describes the physical processes that control dissolution and gas release. Calculation results are shown describing the headspace hydrogen concentration transient during dissolution. The observed spontaneous and induced gas releases from SSTs is summarized and the dissolution of the crust layer in SY-101 is discussed as a recent example of full-scale dissolution of saltcake containing a very large volume of retained gas. The report concludes that the dissolution rate is self limiting and gas release rates are relatively low.
Date: July 31, 2001
Creator: Stewart, Charles W.
System: The UNT Digital Library
FY 2002 Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project (open access)

FY 2002 Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

This document is an integrated monitoring plan for the groundwater project and contains: well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders ("surveillance monitoring"); other, established monitoring plans by reference; and a master well/ constituent/frequency matrix for the entire Hanford Site.
Date: October 31, 2001
Creator: Hartman, Mary J.; Dresel, P Evan; Lindberg, Jonathan W.; Newcomer, Darrell R. & Thornton, Edward C.
System: The UNT Digital Library
High Efficancy Integrated Under-Cabinet Phosphorescent OLED (open access)

High Efficancy Integrated Under-Cabinet Phosphorescent OLED

In this two year program Universal Display Corporation (UDC) together with the University of Michigan, Teknokon, developed and delivered an energy efficient phosphorescent OLED under cabinet illumination system. Specifically the UDC team goal was in 2011 to deliver five (5) Beta level OLED under cabinet lighting fixtures each consisting of five 6-inch x 6-inch OLED lighting panels, delivering over 420 lumens, at an overall system efficacy of >60 lm/W, a CRI of >85, and a projected lifetime to 70% of initial luminance to exceed 20,000 hours. During the course of this program, the Team pursued the commercialization of these OLED based under cabinet lighting fixtures, to enable the launch of commercial OLED lighting products. The UDC team was ideally suited to develop these novel and efficient solid state lighting fixtures, having both the technical experience and commercial distribution mechanisms to leverage work performed under this contract. UDC's business strategy is to non-exclusively license its PHOLED technology to lighting manufacturers, and also supply them with our proprietary PHOLED materials. UDC is currently working with several licensees who are manufacturing OLED lighting panels using our technology. During this 2 year program, we further developed our high efficiency white Phosphorescent OLEDs from the …
Date: October 31, 2001
Creator: Hack, Michael
System: The UNT Digital Library
EMERGE - ESnet/MREN Regional Science Grid Experimental NGI Testbed (open access)

EMERGE - ESnet/MREN Regional Science Grid Experimental NGI Testbed

This document is the final report on the EMERGE Science Grid testbed research project from the perspective of the International Center for Advanced Internet Research (iCAIR) at Northwestern University, which was a subcontractor to this UIC project. This report is a compilation of information gathered from a variety of materials related to this project produced by multiple EMERGE participants, especially those at Electronic Visualization Lab (EVL) at the University of Illinois at Chicago (UIC), Argonne National Lab and iCAIR. The EMERGE Science Grid project was managed by Tom DeFanti, PI from EVL at UIC.
Date: July 31, 2001
Creator: Mambretti, Joe; DeFanti, Tom & Brown, Maxine
System: The UNT Digital Library
Review of Failure Probability Calculations for HFIR Primary Coolant System Piping (open access)

Review of Failure Probability Calculations for HFIR Primary Coolant System Piping

During July 2001, Pacific Northwest National Laboratory was requested by the U.S. Department of Energy, Office of Nuclear Facilities Management, Office of Nuclear Energy, Science and Technology, Germantown, Maryland, to review calculations of piping failure probabilities for the High Flux Test Reactor (HFIR) located at and operated by the Oak Ridge National Laboratory (ORNL). The objective of the failure probability calculations was to estimate the probabilities of large leaks (>1500 gpm) that are of sufficient size to disable the primary coolant system of HFIR to the extent that there is a potential for core damage. PNNL reviewed the computational methods and the inputs to the calculations along with an evaluation of potential failure mechanisms not explicitly addressed by the ORNL calculations. The review concluded that the calculated failure probabilities even with consideration of uncertainties in the calculations and of other potential failure mechanisms provide a high level of confidence that failure frequencies are less than the stated goal of 10-6 piping failures per year.
Date: October 31, 2001
Creator: Simonen, Fredric A.
System: The UNT Digital Library
Intact and Degraded Component Criticality Calculations of N Reactors Spent Nuclear Fuel (open access)

Intact and Degraded Component Criticality Calculations of N Reactors Spent Nuclear Fuel

The objective of this calculation is to perform intact and degraded mode criticality evaluations of the Department of Energy's (DOE) N Reactor Spent Nuclear Fuel codisposed in a 2-Defense High-Level Waste (2-DHLW)/2-Multi-Canister Overpack (MCO) Waste Package (WP) and emplaced in a monitored geologic repository (MGR) (see Attachment I). The scope of this calculation is limited to the determination of the effective neutron multiplication factor (k{sub eff}) for both intact and degraded mode internal configurations of the codisposal waste package. This calculation will support the analysis that will be performed to demonstrate the technical viability for disposing of U-metal (N Reactor) spent nuclear fuel in the potential MGR.
Date: January 31, 2001
Creator: Angers, L.
System: The UNT Digital Library
Enhanced Oil Recovery with Downhole Vibration Stimulation in Osage County, Oklahoma (open access)

Enhanced Oil Recovery with Downhole Vibration Stimulation in Osage County, Oklahoma

This Technical Quarterly Report is for the reporting period September 30, 2001 to December 31, 2001. The report provides details of the work done on the project entitled ''Enhanced Oil Recovery with Downhole Vibration Stimulation in Osage County Oklahoma''. The project is divided into nine separate tasks. Several of the tasks are being worked on simultaneously, while other tasks are dependent on earlier tasks being completed. The vibration stimulation well was permitted as Well 111-W-27, section 8 T26N R6E Osage County Oklahoma. It was spud July 28, 2001 with Goober Drilling Rig No. 3. The well was drilled to 3090-feet cored, logged, cased and cemented. The Rig No.3 moved off August 6, 2001. Phillips Petroleum Co. has performed standard core analysis on the cores recovered from the test well. Standard porosity, permeability and saturation measurements have been conducted. Phillips has begun the sonic stimulation core tests. Calumet Oil Company, the operator of the NBU, has been to collecting both production and injection wells information to establish a baseline for the project in the pilot field test area since May 2001. The 7-inch Downhole Vibration Tool (DHVT) has been built and has been run in a shallow well for initial power …
Date: December 31, 2001
Creator: Brett, J. Ford & Westermark, Robert V.
System: The UNT Digital Library
Enhanced Oil Recovery with Downhole Vibration Stimulation in Osage County Oklahoma (open access)

Enhanced Oil Recovery with Downhole Vibration Stimulation in Osage County Oklahoma

The objective of this project is to demonstrate the impact of downhole vibration stimulation on oil production rates in a mature waterflood field. Oil & Gas Consultants International, Inc. (OGCI) will manage the project in close cooperation with the Osage Tribe as the tests will be conducted in Osage County, Oklahoma, the mineral estate of the Osage Tribe. The field is owned and operated by Calumet Oil Company. Phillips Petroleum Company will contribute their proprietary vibration core analysis of cores recovered from the pilot test area. To achieve the project objectives, the work has been divided into nine tasks, some are concurrent, while other tasks rely on completion of previous steps. The operator, Calumet Oil Company operates several field in Osage County Oklahoma. The North Burbank Unit will be the site of the test. The team will then determine where within the field to optimally locate the vibration test well. With the location determined, the test well will be drilled, cored, logged and 7-inch production casing run and cemented. In a parallel effort, OGCI will be designing, building, and testing a new version of the downhole vibration tool based on their patented and field proven whirling orbital vibrator. With the …
Date: March 31, 2001
Creator: Brett, J. Ford & Westermark, Robert V.
System: The UNT Digital Library
In-Situ Sampling and Characterization of Naturally Occurring Marine Methane Hydrate Using the D/V JOIDES Resolution (open access)

In-Situ Sampling and Characterization of Naturally Occurring Marine Methane Hydrate Using the D/V JOIDES Resolution

The primary accomplishments during the first quarter were to mobilize materials and supplies to meet the deployment schedule for equipment and activities, as proposed under the DOE/NETL cooperative agreement with JOI, with initial testing and use of specialized tools and equipment on Ocean Drilling Program (ODP) Leg 201. As a requirement of the award, two copies of a technical feasibility report entitled ''Preliminary Evaluation of Existing Pressure/Temperature Coring Systems'' were delivered to DOE/NETL on October 22, 2001. The report was written to provide a discussion of the availability and compatibility of the four existing pressure coring devices in existence. Most of these systems are available for use by JOI/ODP aboard the D/V JOIDES Resolution, via purchase, lease, modification, etc. and the proposed capabilities to upgrade existing devices or systems for use on other platforms. In addition, the report provided a discussion of the compatibility of each existing coring device in conjunction with the use of the other coring devices, such as the advanced piston coring (APC) system used by ODP. Based on an evaluation of the JOI report, the DOE/NETL Program Manager William Gwilliam provided a ''Go'' decision to JOI for the further development of the ODP Pressure Coring System …
Date: December 31, 2001
Creator: Rack, Frank
System: The UNT Digital Library
METHANE de-NOX for Utility PC Boilers (open access)

METHANE de-NOX for Utility PC Boilers

The overall project objective is the development and validation of an innovative coal combustion system, based on a novel coal preheating concept prior to combustion, that can reduce NO{sub x} emissions to 0.15 lb/million Btu or less on utility pulverized coal (PC) boilers without the need for post-combustion cleaning. Work during the quarter included initiation of the equipment fabrication effort for all pilot system components. Fabrication of the gas-fired combustor was started and completed by IGT during the quarter. The combustor was then installed in IGT's combustion laboratory for proof-of-performance testing prior to shipping to BBP for installation in the pilot-scale test system. A testing procedure and performance goals were developed for the combustor testing.
Date: March 31, 2001
Creator: Rabovitser, Joseph; Bryan, Bruce & Wohadlo, Stan
System: The UNT Digital Library
Establishment of an Industry-Driven Consortium Focused on Improving the Production Performance of Domestic Stripper Wells (open access)

Establishment of an Industry-Driven Consortium Focused on Improving the Production Performance of Domestic Stripper Wells

None
Date: December 31, 2001
Creator: Morrison, Joel L.
System: The UNT Digital Library
Catalytic Gasification of Coal Using Eutectic Salt Mixtures (open access)

Catalytic Gasification of Coal Using Eutectic Salt Mixtures

Most of the tasks on the project have successfully been completed and reported. A 12 month no-cost extension has been requested to complete the remaining tasks. This report summarizes the accomplishments of the first six months of the no-cost extensions period. The acetic acid extraction showed that acetic acid has more effect on the extraction of the ternary catalyst (LNK) ions than water. Based on the extraction results, the order of the recovery capability of Na{sub 2}CO{sub 3} using acetic acid, sulfuric acid and water extractions is sulfuric acid {ge} acetic acid > water; the order for K{sub 2}CO{sub 3} is sulfuric acid > water >acetic acid; and the order for Li{sub 2}CO{sub 3} is acetic acid > sulfuric acid >water. A process flowsheet for the catalyst recovery process was proposed based on the results. Scanning electron microscopy (SEM) studies showed most of the particles (coal) appear amorphous. Some coal particles are as large as 50-60 {micro}m, but most are smaller. One can also easily see a few crystalline particles (10-20 {micro}m) with sharp facets and corners. The electron micrographs of gasified char samples (reactor-aged) of the LNKcoal mixture showed that a dramatic change is obvious in the morphology and …
Date: March 31, 2001
Creator: Sheth, Atul & Sastry, Chandramouli
System: The UNT Digital Library