Fire protection countermeasures for containment ventilation systems (open access)

Fire protection countermeasures for containment ventilation systems

The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in …
Date: August 25, 1980
Creator: Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H. & Lipska, A.
System: The UNT Digital Library
Measured resolutions of the Arc and Linac BPM systems (open access)

Measured resolutions of the Arc and Linac BPM systems

The 6'' long final focus beam position monitors (short FF BPM's are longer, thus deliver more signal after a 15 nanosecond filter, than either the Linac or Arc monitors. The purpose of this note is to compare the resolution of the Arc vs Linac electronics when applied to a short FF 2'' diameter BPM. A method of calibrating the Arc modules is also tested and briefly discussed. The range of each DAC setting to minimize digitization error is also calculated.
Date: August 25, 1986
Creator: Pappas, D. & Tentindo, S.
System: The UNT Digital Library
Nitrogen oxide abatement by distributed fuel addition (open access)

Nitrogen oxide abatement by distributed fuel addition

The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show that a minimum reburn fuel jet velocity of 15 m/s (standard conditions) was required which is about 80 times the velocity of the primary effluent. The use of nitrogen gas as a transport medium for the reburn fuel was necessary to achieve the desired jet velocities.
Date: August 25, 1989
Creator: Wendt, J. O. L. & Mereb, J. B.
System: The UNT Digital Library
Disposal costs for SRP high-level wastes in borosilicate glass and crystalline ceramic waste forms (open access)

Disposal costs for SRP high-level wastes in borosilicate glass and crystalline ceramic waste forms

Purpose of this document is to compare and contrast the overall burial costs of the glass and ceramic waste forms, including processing, storage, transportation, packaging, and emplacement in a repository. Amount of waste will require approximately 10,300 standard (24 in. i.d. x 9-5/6 ft length) canisters of waste glass, each containing about 3260 lb of waste at 28% waste loading. The ceramic waste form requires about one-third the above number of standard canisters. Approximately $2.5 billion is required to process and dispose of this waste, and the total cost is independent of waste form (glass or ceramic). The major cost items (about 80% of the total cost) for all cases are capital and operating expenses. The capital and 20-year operating costs for the processing facility are the same order of magnitude, and their sum ranges from about one-half of the total for the reference glass case to two-thirds of the total for the ceramic cases.
Date: August 25, 1982
Creator: Rozsa, R.B. & Campbell, J.H.
System: The UNT Digital Library
Review of intense-ion-beam propagation with a view toward measuring ion energy (open access)

Review of intense-ion-beam propagation with a view toward measuring ion energy

The subject of this review is intense ion beam propagation and the possibilities of measuring time dependent ion energy in the beam. Propagation effects discussed include charge separation, charge and current autoneutralization, electron thermalization and current neutralization decay. The interaction of a plasma beam with material obstacles, like collimators, and with transverse magnetic fields is also described. Depending on beam energy, density and pulse length, these interactions can include material ablation with plasmadynamic flow and undeflected propagation across transverse magnetic fields by a polarization drift. On the basis of this review I conclude that three diagnostics: a single floating potential probe, net current probes (Faraday cups) and a Rutherford scattering spectrometer appear capable of giving prompt, time dependent ion energy measurements.
Date: August 25, 1982
Creator: Garcia, M.
System: The UNT Digital Library
On the Nature of the Distortion of a GPHS Fueled Capsule Impacted on Various Media at Various Velocities and Under Various Boundary Conditions; Appendix F: Response of the GPHS Module to LH(Sub-2)-LO(Sub-2) Overpressure in Various Shielded and Unshielded Geometries (open access)

On the Nature of the Distortion of a GPHS Fueled Capsule Impacted on Various Media at Various Velocities and Under Various Boundary Conditions; Appendix F: Response of the GPHS Module to LH(Sub-2)-LO(Sub-2) Overpressure in Various Shielded and Unshielded Geometries

This body of work represents the parametric investigation of conditions of impact for a GPHS fueled capsule.
Date: August 25, 1987
Creator: Eck, Marshall B & Mukunda, Meera
System: The UNT Digital Library
Current to Pressure Transducers for the Argon & Nitrogen Dewars (open access)

Current to Pressure Transducers for the Argon & Nitrogen Dewars

A current to pressure (I/P) transducer will be used in the D-Zero piping system. The transducer is necessary to precisely control the control valve positioners located at the argon and nitrogen dewars. A 4-20 rnA signal will come from the PLC function of the TI565. This electric signal must be converted by the transducer to a pneumatic signal of 3-15 psi which will position the actuator. By doing this, the valve can be opened or closed to any adjusted amount from the control room or a remote I/P controller. A total of 9 transducers will be used at the dewars. The nitrogen dewar will have 3 that are located outside and will have to be weatherproof. The argon dewar will have 6, located inside, that will have to be explosion proof or intrinsically safe.
Date: August 25, 1988
Creator: Serges, T. J.
System: The UNT Digital Library
Nitrogen oxide abatement by distributed fuel addition. Quarterly report No. 8, May 1, 1989--July 31, 1989 (open access)

Nitrogen oxide abatement by distributed fuel addition. Quarterly report No. 8, May 1, 1989--July 31, 1989

The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show that a minimum reburn fuel jet velocity of 15 m/s (standard conditions) was required which is about 80 times the velocity of the primary effluent. The use of nitrogen gas as a transport medium for the reburn fuel was necessary to achieve the desired jet velocities.
Date: August 25, 1989
Creator: Wendt, J. O. L. & Mereb, J. B.
System: The UNT Digital Library
Mars Rover RTG Study (open access)

Mars Rover RTG Study

This report summarizes the results of a Radioisotope Thermoelectric Generator (RTG) design study conducted by Fairchild Space Company at the direction of the U.S. Department of Energy's Office of SpecialApplications, in suppport of the Mars Rover and Sample Return mission under investigation at NASA's Jet Propulsion Laboratory. The report is a rearranged, updated, and significantly expanded amalgam of three interrelated papers presented at the 24th Intersocity Energy Conversion Engineering Conference (IECEC) at Arlington, Virginia, on August 10, 1989.
Date: August 25, 1989
Creator: Schock, Alfred
System: The UNT Digital Library
Texas Poultry: July 1980 (open access)

Texas Poultry: July 1980

Monthly report of the Texas Crop and Livestock Reporting Service on various poultry numbers in Texas and compared with other states. It includes compiled statistics during two years for hatchery production of broiler chicks and turkey poults, egg production, price ratios, poultry slaughtered, cold storage holdings, and chick placements.
Date: August 25, 1980
Creator: Texas Crop and Livestock Reporting Service
System: The Portal to Texas History
Geothermal resources of the Bighorn Basin, Wyoming (open access)

Geothermal resources of the Bighorn Basin, Wyoming

Separate abstracts were prepared for two papers. (MHR)
Date: August 25, 1985
Creator: Heasler, H.P. & Hinckley, B.S.
System: The UNT Digital Library
Parental Kidnapping (open access)

Parental Kidnapping

None
Date: August 25, 1982
Creator: McCoy, Meredith
System: The UNT Digital Library
The Rehabilitation Act of 1973 As Amended by P.L. 97-35, The Omnibus Budget Reconciliation Act of 1981 (open access)

The Rehabilitation Act of 1973 As Amended by P.L. 97-35, The Omnibus Budget Reconciliation Act of 1981

"The attached chart shows the authorization levels established by P.L. 97-35 1/ and compares the House and Senate reconciliation bills for the vocational rehabilitation program" (p. 1).
Date: August 25, 1981
Creator: Smith, Mary F.