Refabrication and Encapsulation of Highly Irradiated Uranium Dioxide (open access)

Refabrication and Encapsulation of Highly Irradiated Uranium Dioxide

Abstract: One hundred gram quantities of uranium dioxide, irradiated to burnup as great as 21,000 Mwd/MTU and previously reprocessed by AIROX (Atomics International Reduction Oxidation), were refabricated into high density pellets and encapsulated for re-irradiation.
Date: December 1, 1964
Creator: Guon, J.; Bodine, J. E. & Sullivan, R. J.
System: The UNT Digital Library
The Facility 350 Helium-Atmosphere System (open access)

The Facility 350 Helium-Atmosphere System

Report describing the helium atmosphere system in the Argonne National Laboratory's Facility 350. The atmosphere's ability to remove moisture, oxygen, and other impurities, how the atmosphere is purified, and experimental data regarding the use of activated carbon to absorb oxygen from helium are discussed.
Date: December 1962
Creator: Mayfield, R. M.; Tope, W. G. & Shuck, A. B.
System: The UNT Digital Library
Oak Ridge Analytical Chemistry Division Annual Progress Report: 1963 (open access)

Oak Ridge Analytical Chemistry Division Annual Progress Report: 1963

Report containing the ongoing research and development of the Oak Ridge National laboratory's Analytical Chemistry Division.
Date: 1964-12~
Creator: Oak Ridge National Laboratory. Analytical Chemistry Division.
System: The UNT Digital Library
Investigations of Domestic Radioactive Raw Materials, Beryllium, and Other Trace Elements, Monthly Report: November 1951 (open access)

Investigations of Domestic Radioactive Raw Materials, Beryllium, and Other Trace Elements, Monthly Report: November 1951

Monthly report of the U.S. Geological Survey's trace element investigations including an outline of field work, laboratory work, and staff activities that have been completed or are in process.
Date: 1951-12~
Creator: Geological Survey (U.S.). Trace Elements Office.
System: The UNT Digital Library
Second Report on Liquid Metal Level Instrument (open access)

Second Report on Liquid Metal Level Instrument

The liquid metal level instrument will operate at tank temperatures up to 1000 F. Overall system accuracy depends on operating conditions, as described in the report. Test accuracies from 2 to 8% have been obtained from full to empty tank. The primary detector unit successfully passed navy HI shock test.
Date: December 21, 1954
Creator: Droma, Clarence R.
System: The UNT Digital Library
A Review of Supercritical Fluid Extraction (open access)

A Review of Supercritical Fluid Extraction

Forward: The purpose of this report is to summarize the results obtained from a brief investigation of supercritical fluid extraction principles and applications. This study was one portion of a project funded by the U.S. Department of Energy, Office of Fossil Energy, contract nuriber DE-AI01076PR06010, in response to a preliminary proposal submitted by the authors. This report sometimes uses company trade naries to identify processes and patent holders. This usage implies no endorsement by HBS. Note also that some figures reproduced from other sources do not conform with NBS policy concerning SI units.
Date: December 1983
Creator: Ely, James F. & Baker, Jolene K.
System: The UNT Digital Library