Errors in skin temperature measurements. (open access)

Errors in skin temperature measurements.

Numerical simulation is used to investigate the accuracy of a direct-contact device for measuring skin-surface temperature. A variation of thermal conductivity of the foam has greater effect on the error rather than a variation of the blood perfusion rate. For a thermal conductivity of zero, an error of 1.5 oC in temperature was identified. For foam pad conductivities of 0.03 and 0.06 W/m-oC, the errors are 0.5 and 0.15 oC. For the transient study, with k=0 W/m-oC, it takes 4,900 seconds for the temperature to reach steady state compared with k=0.03 W/m-oC and k=0.06 W/m-oC where it takes 3,000 seconds. The configuration without the foam and in presence of an air gap between the skin surface and the sensor gives the most uniform temperature profile.
Date: December 2008
Creator: Dugay, Murielle
System: The UNT Digital Library
Experimental Investigation on Efficiency of Fresnel Lenses with Different Manufacturing Methods (open access)

Experimental Investigation on Efficiency of Fresnel Lenses with Different Manufacturing Methods

Non-imaging Fresnel lenses have been playing an important role in improving the efficiency of the solar energy systems. Many researchers and scientists have devoted their research to optimize the design of the Fresnel lenses. Before it can contribute to energy efficiency increase, a Fresnel lens with optimized design will first need to be fabricated with the most cost-effective method as well as the best quality fabrication as possible. If targeted in a commercial market, feasibility of mass production with a minimum fabrication time would also be a consideration. To bring the design optimization of a Fresnel lens from a conceptual theory to a real-life increase in energy efficiency, the lens needs to be fabricated, tested, compared, and analyzed. This research thesis is intended to explore the performance of the lenses with optimized design through experimental investigations. The design optimization was achieved by a previous PhD student at UNT. A total of six lenses fabricated with four different methods along with two purchased lenses were tested with two different approaches. Multiple testing routes were conducted within a 10-month period to observe the effects of material decomposition and degradation on the lens performance. The resulting experimental data has provided a solid base …
Date: December 2020
Creator: Sexton, Ai Jiang
System: The UNT Digital Library