LOFT diesel generator ''A'' exhaust stack seismic analysis (open access)

LOFT diesel generator ''A'' exhaust stack seismic analysis

A stress analysis of the LOFT Diesel Generator ''A'' Exhaust Stack was performed to determine its reaction to Safe-Shutdown Earthquake loads. The exhaust stack silencer and supporting foundation was found to be inadequate for the postulated seismic accelerations. Lateral support is required to prevent overturning of the silencer pedestal and reinforcement of the 4'' x 0.5'' silencer base straps is necessary. Basic requirements for this additional support are discussed.
Date: May 12, 1978
Creator: Blandford, R.K.
System: The UNT Digital Library
LOFT CIS Analysis Line 2 inches-IA-298-AB outside containment penetration S-2A (open access)

LOFT CIS Analysis Line 2 inches-IA-298-AB outside containment penetration S-2A

Line 2''-IA-295-AB outside containment penetration S-2A was analyzed to ASME Section III, Subsection NC (Class 2) criteria. The line is part of the Containment Isolation System. The model considered the line from the penetration outward through the first isolation valve. Results of the analysis show that this section of the line meets Class 2 requirements without modification.
Date: September 12, 1978
Creator: Pierce, A.T.
System: The UNT Digital Library
LOFT CIS analysis 2''-IA-299-AB inside containment penetration S-5B (open access)

LOFT CIS analysis 2''-IA-299-AB inside containment penetration S-5B

A stress analysis was performed on the 2''-IA-299-AB pipe system inside containment penetration S-5B. Deadweight, thermal expansion and seismic loads were considered. The results indicate that this piping will meet ASME Section III, Class 2 requirements.
Date: September 12, 1978
Creator: Morton, D.K.