Resource Type

Serial/Series Title

Description, calibration and sensitivity analysis of the local ecosystem submodel of a global model of carbon and nitrogen cycling and the water balance in the terrestrial biosphere (open access)

Description, calibration and sensitivity analysis of the local ecosystem submodel of a global model of carbon and nitrogen cycling and the water balance in the terrestrial biosphere

We have developed a geographically-distributed ecosystem model for the carbon, nitrogen, and water dynamics of the terrestrial biosphere TERRA. The local ecosystem model of TERRA consists of coupled, modified versions of TEM and DAYTRANS. The ecosystem model in each grid cell calculates water fluxes of evaporation, transpiration, and runoff; carbon fluxes of gross primary productivity, litterfall, and plant and soil respiration; and nitrogen fluxes of vegetation uptake, litterfall, mineralization, immobilization, and system loss. The state variables are soil water content; carbon in live vegetation; carbon in soil; nitrogen in live vegetation; organic nitrogen in soil and fitter; available inorganic nitrogen aggregating nitrites, nitrates, and ammonia; and a variable for allocation. Carbon and nitrogen dynamics are calibrated to specific sites in 17 vegetation types. Eight parameters are determined during calibration for each of the 17 vegetation types. At calibration, the annual average values of carbon in vegetation C, show site differences that derive from the vegetation-type specific parameters and intersite variation in climate and soils. From calibration, we recover the average C{sub v} of forests, woodlands, savannas, grasslands, shrublands, and tundra that were used to develop the model initially. The timing of the phases of the annual variation is driven by …
Date: October 1, 1995
Creator: Kercher, J. R. & Chambers, J. Q.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-C-111 (in situ): Results from samples collected on 6/20/94 (open access)

Vapor space characterization of waste Tank 241-C-111 (in situ): Results from samples collected on 6/20/94

This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-C-111 (referred to as Tank C-111). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Summary Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), hydrogen cyanide (HCN), and water vapor (H{sub 2}O). Sampling for sulfur oxides was not requested. Organic compounds were quantitatively determined. Five organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 40 standard TO-14 analytes and observed 39. None of these compounds were above the 2-ppbv calibrated instrumental detection limit. However, it is believed that the detection of dichlorodifluoromethane and methyl benzene are real at these low concentrations. The five organic analytes with the highest estimated concentrations are listed in Summary Table 1. The …
Date: October 1, 1995
Creator: Ligotke, M. W.; Pool, K. H.; Lucke, R. B.; McVeety, B. D.; Clauss, T. W.; McCulloch, M. et al.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-C-104: Results from samples collected on 2/17/94 and 3/3/94 (open access)

Vapor space characterization of waste Tank 241-C-104: Results from samples collected on 2/17/94 and 3/3/94

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-C-104 (referred to as Tank C-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Summary Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), sulfur oxides (SO{sub x}), and water vapor (H{sub 2}O). Organic compounds were also quantitatively determined. Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were analyzed for tributyl phosphate. Twenty-four organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 40 standard TO-14 analytes. Of these, two were observed above the 2-ppbv calibrated instrument detection limit. The 10 organic analytes with the highest estimated concentrations are listed in Summary Table 1. These 10 analytes account for approximately 88% of the total organic components in Tank …
Date: October 1, 1995
Creator: Lucke, R. B.; McVeety, B. D.; Clauss, T. W.; Pool, K. H.; Young, J. S.; McCulloch, M. et al.
System: The UNT Digital Library
Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94 (open access)

Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94

This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T. J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.5. The sample job was designated S4077, and samples were collected by WHC on October 26, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses), and six SUMMA{trademark} canisters (for organic analyses) were supplied to the WHC sampling staff on October 24. Samples were taken (by …
Date: October 1, 1995
Creator: Clauss, T. W.; Ligotke, M. W. & Pool, K. H.
System: The UNT Digital Library
Vapor space characterization of waste tank 241-BY-106: Results from samples collected through the vapor sampling system on July 8, 1994 (open access)

Vapor space characterization of waste tank 241-BY-106: Results from samples collected through the vapor sampling system on July 8, 1994

This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-BY-106. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1, 1995
Creator: Lucke, R. B.; Pool, K. H.; Ligotke, M. W.; Clauss, T. W.; McVeety, B. D.; Fruchter, J. S. et al.
System: The UNT Digital Library
Californium-252: a remarkable versatile radioisotope (open access)

Californium-252: a remarkable versatile radioisotope

A product of the nuclear age, Californium-252 ({sup 252}Cf) has found many applications in medicine, scientific research, industry, and nuclear science education. Californium-252 is unique as a neutron source in that it provides a highly concentrated flux and extremely reliable neutron spectrum from a very small assembly. During the past 40 years, {sup 252}Cf has been applied with great success to cancer therapy, neutron radiography of objects ranging from flowers to entire aircraft, startup sources for nuclear reactors, fission activation for quality analysis of all commercial nuclear fuel, and many other beneficial uses, some of which are now ready for further growth. Californium-252 is produced in the High Flux Isotope Reactor (HFIR) and processed in the Radiochemical Engineering Development Center (REDC), both of which are located at the Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The REDC/HFIR facility is virtually the sole supplier of {sup 252}Cf in the western world and is the major supplier worldwide. Extensive exploitation of this product was made possible through the {sup 252}Cf Market Evaluation Program, sponsored by the United States Department of Energy (DOE) [then the Atomic Energy Commission (AEC) and later the Energy Research and Development Administration (ERDA)]. This program included …
Date: October 10, 1995
Creator: Osborne-Lee, I.W. & Alexander, C.W.
System: The UNT Digital Library
California Cooperative Oceanic Fisheries Investigations: Reports. Volume 36, January 1 to December 31, 1994 (open access)

California Cooperative Oceanic Fisheries Investigations: Reports. Volume 36, January 1 to December 31, 1994

California Cooperative Oceanic Fisheries Investigations (CalCOFI) performs research in the area of sampling physical, chemical, and biological variables in the California Current. The information received is stored in databases and gives a better understanding of the physics and chemistry of the California Current. Their effect on the food chain make it possible to view current oceanographic and biological conditions in the context of the long term. Measurements taken during 1994 and early 1995 on CalCOFI cruises have indicated a return to normal conditions after anomalous conditions that dominated the two preceding years. The data have permitted an increasingly prompt assessment of the state of the California Current system off southern California. This report also contains papers presented at the CalCOFI conference in 1994 regarding the 1991--92 El Nino and its impact on fisheries. In addition, individual scientific contributions are included which provide an additional understanding of the processes involved in the California Current.
Date: October 1, 1995
Creator: Olfe, J.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-TX-118 (in situ): Results from samples collected on 9/7/94 (open access)

Vapor space characterization of waste Tank 241-TX-118 (in situ): Results from samples collected on 9/7/94

This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-TX-118 (referred to as Tank TX-118). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), hydrogen cyanide (CHN), and water (H{sub 2}O). Sampling for sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 13 analytes. Hexane, normally included in the additional analytes, was removed because a calibration standard was not available during analysis of Tank TX-118 SUMMA{trademark} canisters. Of these, 12 were observed above the 5-ppbv reporting cutoff. Fourteen tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 86% of the total organic components …
Date: October 1, 1995
Creator: Thomas, B. L.; Clauss, T. W.; Ligotke, M. W.; Pool, K. H.; McVeety, B. D.; Olsen, K. B. et al.
System: The UNT Digital Library
Vapor space characterization of Waste Tank 241-S-111: Results from samples collected on 3/21/95 (open access)

Vapor space characterization of Waste Tank 241-S-111: Results from samples collected on 3/21/95

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-S-111 (referred to as Tank S-111). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, seven were observed above the 5-ppbv reporting cutoff. Five tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 98% of the total organic components in Tank S-111. Two permanent gases, hydrogen (H{sub 2}) and nitrous oxide (N{sub 2}O), were also detected. Tank S-111 is on the Hydrogen Watch …
Date: October 1, 1995
Creator: Klinger, G. S.; Clauss, T. W. & Ligotke, M. W.
System: The UNT Digital Library
Vapor space characterization of Waste Tank 241-U-105: Results from samples collected on 2/24/95 (open access)

Vapor space characterization of Waste Tank 241-U-105: Results from samples collected on 2/24/95

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-105 (referred to as Tank U-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Three tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. All nine of the organic analytes identified are listed in Table 1 and account for 100% of the total organic components in Tank U-105. Nitrous oxide (N{sub 2}O) was the only permanent gas detected in the tank-headspace sample. Tank U-105 is on the Hydrogen Watch List.
Date: October 1, 1995
Creator: Pool, K. H.; Clauss, T. W. & Ligotke, M. W.
System: The UNT Digital Library
Waste Tank Vapor Program: Vapor space characterization of waste tank 241-C-110. Results from samples collected on August 18, 1994 (open access)

Waste Tank Vapor Program: Vapor space characterization of waste tank 241-C-110. Results from samples collected on August 18, 1994

This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 24l-C-110. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1, 1995
Creator: Ligotke, M. W.; Clauss, T. W. & Pool, K. H.
System: The UNT Digital Library
Vapor space characterization of Waste Tank 241-U-107: Results from samples collected on 2/17/95 (open access)

Vapor space characterization of Waste Tank 241-U-107: Results from samples collected on 2/17/95

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-107 (referred to as Tank U-107). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 10 were observed above the 5-ppbv reporting cutoff. Sixteen organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 88% of the total organic components in Tank U-107. Nitrous oxide (N{sub 2}O) was the only permanent gas detected in the tank-headspace samples. Tank U-107 is on the Organic …
Date: October 1, 1995
Creator: McVeety, B. D.; Clauss, T. W. & Ligotke, M. W.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-BY-108: Results from samples collected on 10/27/94 (open access)

Vapor space characterization of waste Tank 241-BY-108: Results from samples collected on 10/27/94

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BY-108 (referred to as Tank BY-108). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water vapor (H{sub 2}O). Trends in NH{sub 3} and H{sub 2}O samples indicated a possible sampling problem. Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, the authors looked for the 40 TO-14 compounds plus an additional 15 analytes. Of these, 17 were observed above the 5-ppbv reporting cutoff. Also, eighty-one organic tentatively identified compounds (TICs) were observed above the reporting cutoff (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The nine organic analytes with the highest estimated concentrations are listed in Summary Table 1 and account for approximately 48% of the total organic components in the headspace of Tank BY-108. Three permanent …
Date: October 1, 1995
Creator: McVeety, B. D.; Clauss, T. W. & Ligotke, M. W.
System: The UNT Digital Library
Vapor space characterization of waste tank 241-TY-103: Results from samples collected on 4/11/95 (open access)

Vapor space characterization of waste tank 241-TY-103: Results from samples collected on 4/11/95

This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TY-103 (referred to as Tank TY-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 16 were observed above the 5-ppbv reporting cutoff. Sixteen tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 95% of the total organic components in Tank TY-103. Two permanent gases, carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O), were also detected.
Date: October 1, 1995
Creator: Ligotke, M. W.; Clauss, T. W. & Pool, K. H.
System: The UNT Digital Library
Waste Tank Vapor Program: Vapor space characterization of waste tank 241;C-102: Results from samples collected on August 23, 1994 (open access)

Waste Tank Vapor Program: Vapor space characterization of waste tank 241;C-102: Results from samples collected on August 23, 1994

This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-C-102. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1, 1995
Creator: Klinger, G. S.; Clauss, T. W. & Ligotke, M. W.
System: The UNT Digital Library
Cancer and birth defects surveillance system for communities around the Savannah River Site: Phase 2 -- Birth defects. Technical progress report, year 01 (open access)

Cancer and birth defects surveillance system for communities around the Savannah River Site: Phase 2 -- Birth defects. Technical progress report, year 01

The Savannah River Region Health Information System Birth Defects Registry (SRRHIS-BDR) began on September 30, 1994. As with the SRRHIS Cancer Registry, surveillance of the 12 Georgia counties was subcontracted to Emory University School of Public Health. Collaborative efforts between the Medical University of South Carolina (MUSC) and Emory University staffs have been characterized by warm relationships and commitment to developing a state of the art registry. As a result of early planning efforts, the authors were able to actually activate the data collection. As of the end of September 1995, partial data from the 1994 birth cohort and up-to-date data for the 1995 birth cohort had been collected on the South Carolina side. The Georgia Staff started later and have not yet caught up to the 1994 level. South Carolina was able to start earlier because they were fortunate to quickly recruit an abstractor. Also, by the end of the first year, an innovative automated data entry system for laptop computers was developed by the computer staff to facilitate and improve data collection.
Date: October 1, 1995
Creator: Dunbar, J.B.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-C-109 (in situ): Results from samples collected on 6/23/94 (open access)

Vapor space characterization of waste Tank 241-C-109 (in situ): Results from samples collected on 6/23/94

This report describes organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-C-109 (referred to as Tank C-109). The results described here were obtained to support safety and toxicological evaluations. Organic compounds were quantitatively determined. Thirteen organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 40 standard TO-14 analytes. Of these, only one was observed above the 2-ppbv calibrated instrumental detection limit. However, it is believed, even though the values for dichlorodifluoromethane and trichlorofluoromethane are below the instrumental detection limit, they are accurate at these low concentrations. The six analytes account for approximately 100% of the total organic components in Tank C-109. These six organic analytes with the highest estimated concentrations are listed in Summary Table 1. Detailed descriptions of the results appear in the text.
Date: October 1, 1995
Creator: Clauss, T. W.; Ligotke, M. W.; Pool, K. H.; Lucke, R. B.; McVeety, B. D.; Sharma, A. K. et al.
System: The UNT Digital Library
Vapor space characterization of waste Tank 241-BY-104 (in situ): Results from samples collected on 4/22/94 (open access)

Vapor space characterization of waste Tank 241-BY-104 (in situ): Results from samples collected on 4/22/94

This report describes inorganic and organic analyses results from in situ samples obtained from the space of the Hanford waste storage Tank 241-BY-104 (referred to as Tank BY-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds NH{sub 3}, NO{sub 2}, NO, HCN, and H{sub 2}O. Sampling for sulfur oxides was not requested. Several organic compounds were also quantitatively determined. Eighty-nine tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semi-quantitative estimates. In addition, the 41 standard TO 14 analytes were sought. Of these, only a few were observed above the 2-ppbv detection limit. The 10 organic analytes with the highest estimated concentrations are listed in Table 1. These 10 analytes account for approximately 48% of the total organic components in the headspace of Tank BY-104. Detailed results appear in the text. Tank BY-104 is on the Ferrocyanide Watch List.
Date: October 1, 1995
Creator: Pool, K. H.; Ligotke, M. W.; Clauss, T. W.; Lucke, R. B.; McVeety, B. D.; Sharma, A. K. et al.
System: The UNT Digital Library
Waste Tank Vapor Program: Vapor space characterization of waste tank 241-T-111. Results from samples collected on January 20, 1995 (open access)

Waste Tank Vapor Program: Vapor space characterization of waste tank 241-T-111. Results from samples collected on January 20, 1995

This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-T-111. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1995
Creator: Klinger, G. S.; Clauss, T. W.; Ligotke, M. W.; Pool, K. H.; McVeety, B. D.; Olsen, K. B. et al.
System: The UNT Digital Library
Variability and scaling of hydraulic properties for 200 Area soils, Hanford Site (open access)

Variability and scaling of hydraulic properties for 200 Area soils, Hanford Site

Over the years, data have been obtained on soil hydraulic properties at the Hanford Site. Much of these data have been obtained as part of recent site characterization activities for the Environmental Restoration Program. The existing data on vadose zone soil properties are, however, fragmented and documented in reports that have not been formally reviewed and released. This study helps to identify, compile, and interpret all available data for the principal soil types in the 200 Areas plateau. Information on particle-size distribution, moisture retention, and saturated hydraulic conductivity (K{sub s}) is available for 183 samples from 12 sites in the 200 Areas. Data on moisture retention and K{sub s} are corrected for gravel content. After the data are corrected and cataloged, hydraulic parameters are determined by fitting the van Genuchten soil-moisture retention model to the data. A nonlinear parameter estimation code, RETC, is used. The unsaturated hydraulic conductivity relationship can subsequently be predicted using the van Genuchten parameters, Mualem`s model, and laboratory-measured saturated hydraulic conductivity estimates. Alternatively, provided unsaturated conductivity measurements are available, the moisture retention curve-fitting parameters, Mualem`s model, and a single unsaturated conductivity measurement can be used to predict unsaturated conductivities for the desired range of field moisture …
Date: October 1, 1995
Creator: Khaleel, R. & Freeman, E. J.
System: The UNT Digital Library
Sludge mobilization with submerged nozzles in horizontal cylindrical tanks (open access)

Sludge mobilization with submerged nozzles in horizontal cylindrical tanks

The Melton Valley Storage Tanks (MVSTs) and the evaporator service tanks at the Oak Ridge National Laboratory (ORNL) are used for the collection and storage of liquid low-level waste (LLLW). Wastes collected in these tanks are typically acidic when generated and are neutralized with sodium hydroxide to protect the tanks from corrosion; however, the high pH of the solution causes the formation of insoluble compounds that precipitate. These precipitates formed a sludge layer approximately 0.6 to 1.2 m (2 to 4 ft) deep in the bottom of the tanks. The sludge in the MVSTs and the evaporator service tanks will eventually need to be removed from the tanks and treated for final disposal or transferred to another storage facility. The primary options for removing the sludge include single-point sluicing, use of a floating pump, robotic sluicing, and submerged-nozzle sluicing. The objectives of this study were to (1) evaluate the feasibility of submerged-nozzle sluicing in horizontal cylindrical tanks and (2) obtain experimental data to validate the TEMPEST (time-dependent, energy, momentun, pressure, equation solution in three dimensions) computer code.
Date: October 1995
Creator: Hylton, T. D.; Cummins, R. L.; Youngblood, E. L. & Perona, J. J.
System: The UNT Digital Library
Vapor space characterization of waste tank 241-C-112: Results from samples collected on 8/11/94 (open access)

Vapor space characterization of waste tank 241-C-112: Results from samples collected on 8/11/94

This report describes organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-C-112 (referred to as Tank C-112). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. Organic compounds were also quantitatively determined. Five organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. None were observed above the 2-ppbv detection limit. The five organic analytes with the highest concentration are listed in Table 1 and account for 100% of the total organic components in Tank C-112.
Date: October 1, 1995
Creator: Ligotke, M. W.; McVeety, B. D. & Pool, K. H.
System: The UNT Digital Library
Vapor space characterization of Waste Tank 241-U-106 (in situ): Results from samples collected on 8/25/94 (open access)

Vapor space characterization of Waste Tank 241-U-106 (in situ): Results from samples collected on 8/25/94

This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-U-106 (referred to as Tank U-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 target analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Ten organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv in two or more of the three samples collected and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 89% of the total organic components in Tank U-106. Methyl isocyanate, a compound of possible concern in …
Date: October 1, 1995
Creator: Ligotke, M. W.; Lucke, R. B. & Pool, K. H.
System: The UNT Digital Library
Vapor space characterization of Waste Tank 241-TY-104 (in situ): Results from samples collected on 8/5/94 (open access)

Vapor space characterization of Waste Tank 241-TY-104 (in situ): Results from samples collected on 8/5/94

This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-TY-104 (referred to as Tank TY-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 analytes. Of these, eight were observed above the 5-ppbv reporting cutoff. Twenty-four organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 86% of the total organic components in Tank TY-104. Tank TY-104 is on the Ferrocyanide Watch List.
Date: October 1, 1995
Creator: Ligotke, M. W.; Pool, K. H. & Lucke, R. B.
System: The UNT Digital Library