A Next-to-Leading-Order QCD Analysis of Neutrino-Iron Structure Functions at the Tevatron (open access)

A Next-to-Leading-Order QCD Analysis of Neutrino-Iron Structure Functions at the Tevatron

Nucleon structure functions measured in neutrino-iron and antineutrino-iron charged-current interactions are presented. The data were taken in two high-energy high-statistics runs by the LAB-E detector at the Fermilab Tevatron. Structure functions are extracted from a sample of 950,000 neutrino and 170,000 antineutrino events with neutrino energies from 30 to 360 GeV. The structure functions F{sub 2} and xF{sub 3} are compared with the predictions of perturbative Quantum Chromodynamics (PQCD). The combined non-singlet and singlet evolution in the context of PQCD gives value of {Lambda}NLO,(4)/MS = 337 {+-} 28 (exp.) MeV, which corresponds to {alpha}{sub S}(M{sub Z}{sup 2}) = 0.119 {+-} 0.002 (exp.) {+-} 0.004 (theory), and with a gluon distribution given by xG(x,Q{sub 0}{sup 2} = 5GeV{sup 2}) = (2.22 {+-} 0.34) {times} (1 {minus} x){sup 4.65{+-}0.68}.
Date: June 1, 1997
Creator: Seligman, W. G.
System: The UNT Digital Library
Speciation of chromium and manganese using pneumatically assisted electrospray mass spectrometry (open access)

Speciation of chromium and manganese using pneumatically assisted electrospray mass spectrometry

It is not an exaggeration to say that much of chemistry involves ions in solution. A technique which allows for ions to be transferred from solution into the gas phase and subsequently analyzed by mass spectrometric detection would be of importance. If structural information, representative of the solution chemistry could be gained from these gas-phase ions, this would also be important. Electrospray mass spectrometry (ES-MS) is such a technique.
Date: February 1, 1997
Creator: Gwizdala, A.B. III
System: The UNT Digital Library
A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter (open access)

A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10{degrees}C to 30{degrees}C. Humidity effects were …
Date: September 1, 1997
Creator: Apte, M.G.
System: The UNT Digital Library