RANDOM AND SYSTEMATIC FIELD ERRORS IN THE SNS RING: A STUDY OF THEIR EFFECTS AND COMPENSATION (open access)

RANDOM AND SYSTEMATIC FIELD ERRORS IN THE SNS RING: A STUDY OF THEIR EFFECTS AND COMPENSATION

The Accumulator Ring for the proposed Spallation Neutron Source (SNS) [l] is to accept a 1 ms beam pulse from a 1 GeV Proton Linac at a repetition rate of 60 Hz. For each beam pulse, 10{sup 14} protons (some 1,000 turns) are to be accumulated via charge-exchange injection and then promptly extracted to an external target for the production of neutrons by spallation. At this very high intensity, stringent limits (less than two parts in 10,000 per pulse) on beam loss during accumulation must be imposed in order to keep activation of ring components at an acceptable level. To stay within the desired limit, the effects of random and systematic field errors in the ring require careful attention. This paper describes the authors studies of these effects and the magnetic corrector schemes for their compensation.
Date: June 22, 1998
Creator: Gardner, C. J.; Lee, Y. Y. & Weng, W. T.
System: The UNT Digital Library
Cost and performance analysis of conceptual designs of physical protection systems (open access)

Cost and performance analysis of conceptual designs of physical protection systems

CPA -- Cost and Performance Analysis -- is a methodology that joins Activity Based Cost (ABC) estimation with performance based analysis of physical protection systems. CPA offers system managers an approach that supports both tactical decision making and strategic planning. Current exploratory applications of the CPA methodology are addressing analysis of alternative conceptual designs. To support these activities, the original architecture for CPA, is being expanded to incorporate results from a suite of performance and consequence analysis tools such as JTS (Joint Tactical Simulation), ERAD (Explosive Release Atmospheric Dispersion) and blast effect models. The process flow for applying CPA to the development and analysis conceptual designs is illustrated graphically.
Date: June 1, 1998
Creator: Hicks, M. J.; Snell, M. S.; Sandoval, J. S. & Potter, C. S.
System: The UNT Digital Library
Progress towards sub-micron hard x-ray imaging using elliptically bent mirrors and its applications (open access)

Progress towards sub-micron hard x-ray imaging using elliptically bent mirrors and its applications

The authors have developed an x-ray micro-probe facility utilizing mirror bending techniques that allow white light x-rays (4--12keV) from the Advanced light Source Synchrotron to be focused down to spot sizes of micron spatial dimensions. They have installed a 4 crystal monochromator prior to the micro-focusing mirrors. The monochromator is designed such that it can move out of the way of the input beam, and allows the same micron sized sample to be illuminated with either white or monochromatic radiation. Illumination of the sample with white light allows for elemental mapping and Laue x-ray diffraction, while illumination of the sample with monochromatic light allows for elemental mapping (with reduced background), micro-X-ray absorption spectroscopy and micro-diffraction. The performance of the system will be described as will some of the initial experiments that cover the various disciplines of Earth, Material and Life Sciences.
Date: June 1998
Creator: MacDowell, A. A.; Lamble, G. M.; Celestre, R. S.; Padmore, H. A.; Chang, C. H. & Patel, J. R.